USING LOGICAL PROCESSING7-4 XEROX DOCUPRINT 180 LPS PDL REFERENCECHANGEThis parameter defines test specifications for a logical processingfunction with change mode criteria.Syntax CRITERIA CHANGE =option(s)Options Table 7-3 lists the parameter option(s) and definition(s).There is no default.Table 7-3. CHANGE parameter option(s) and definition(s)Option(s) Definition(s)offset The offset in bytes (relative to zero) from the start ofthe user’s portion of the record to the control fieldwithin the record or from the start of the physical tapeblock to the control field within the block.length The length in bytes of the control field. Its range is 1to 255.NE Indicates not equal to.LAST Indicates that the control field of the current record(or block) is being compared to the control field of theprevious (last encountered) record (or block). If acontrol field of the current record (or block) is lessthan the specified length, the comparison is not doneand the test fails. (For online and HIP jobs, wheretrailing blanks are truncated by the host, control fieldswhich are less than the specified length may bepadded with blanks so that a comparison can bedone. If you are using a value less than the lengthspecified, or if the number is the same but less thanzero, the values are not internally the same and thus,the test is met.)