Index-Sub Type RW Default Value range Unit Description0x7100-05* U08 R 0 0 … 0xFF Digital input states I/O1...I/O4Ä ‘Explanation of the elements’ on page 97This object contains the current values of the digital inputs I/O1...I/O4. They also can befound in the I/O area.Please note if you write via the Acyclic Channel to objects, which aremapped in the I/O area, these values are overwritten with the next cycle.Bit 3 ... 03 2 1 0 Descriptionx x x 0 Input I/O1 has signal "0"x x x 1 Input I/O1 has signal "1"x x 0 x Input I/O2 has signal "0"x x 1 x Input I/O2 has signal "1"x 0 x x Input I/O3 has signal "0"x 1 x x Input I/O3 has signal "1"0 x x x Input I/O4 has signal "0"1 x x x Input I/O4 has signal "1"5.2.6 Digital output I/O1...I/O4 - 0x7200Index-Sub Type RW Default Value range Unit Description0x7200-00 U08 R 8 8 Digital outputs - number of entriesÄ ‘Explanation of the elements’ on page 97Ä Chapter 4.9 ‘Deployment I/O1...I/O4’ on page 790x7100-05 - Digital inputstates I/O1...I/O40x7200-00 - Digital outputs- number of entriesVIPA System SLIO Object dictionaryObjects > Digital output I/O1...I/O4 - 0x7200HB300 | FM | 054-1CB00 | en | 18-06 105