Index-Sub Type RW Default Value range Unit Description0x8680-12 U16 R/W 800 0 … 4000 [0.01V] Control voltage power stage min. error levelÄ ‘Explanation of the elements’ on page 97This object specifies a lower limit for the control voltage of the power stage. If the limit isundershot, viaÄ ‘0x8100-02 - Status word’ on page 110 respectivelyÄ ‘0x8100-06 -Error active bits’ on page 115 an error is shown.Index-Sub Type RW Default Value range Unit Description0x8680-13 U16 R/W 1400 0 … 4000 [0.01V] Control voltage power stage max. errorlevelÄ ‘Explanation of the elements’ on page 97This object specifies an upper limit for the control voltage of the power stage. If the limit isexceeded, viaÄ ‘0x8100-02 - Status word’ on page 110 respectivelyÄ ‘0x8100-06 -Error active bits’ on page 115 an error is shown.5.2.18 Temperatures - 0x8780Index-Sub Type RW Default Value range Unit Description0x8780-00 U08 R 12 12 Temperatures - number of entriesÄ ‘Explanation of the elements’ on page 97Index-Sub Type RW Default Value range Unit Description0x8780-02 S16 R 0 -50 … 120 [degC] Temperature μ-Controller actual valueÄ ‘Explanation of the elements’ on page 97This object specifies the measured temperature of the μ-Controller of the motion module.0x8680-12 - Controlvoltage power stage min.error level0x8680-13 - Controlvoltage power stage max.error level0x8780-00 - Temperatures- number of entries0x8780-02 - Temperatureμ-Controller actual valueVIPA System SLIO Object dictionaryObjects > Temperatures - 0x8780HB300 | FM | 054-1CB00 | en | 18-06 139