9 Web InterfaceYASKAWA SIEP C730600 89E PROFINET Technical Manual 47Name DescriptionSingle Collisions Cumulative number of single collisions.Multiple Collisions Cumulative number of multiple collisions.Late Collisions Cumulative number of late collisions.Deferred Collisions Cumulative number of deferred collisions.Excessive Collisions Cumulative number of excessive collisions.Frame Too Large Cumulative number of frames that exceed the maximum frame size.Note:Cumulative counters are reset when the power supply is cycled.◆ Chart PageThe Chart page can be used to monitor one signal from a predefined list.List:• Frequency Reference• Output Frequency• Output Current• Motor Speed• Torque Reference• DC Bus Voltage• Terminal Analog Input 1• Terminal Analog Input 2• Terminal Analog Input 3Figure 9.4 Chart Page View◆ Email Alerts PageThe Email Alerts page allows the user to configure four Email Fault/Alarm conditions. When the condition is true,one email will be sent to the provided email address. Another email will not be sent until the condition becomesfalse and then true again. A 30-second timer prevents emails from being sent when conditions reoccurimmediately after being removed. The timer helps limit the amount of emails sent regarding the same intermittentcondition and helps to reduce network traffic by reducing emails about reoccurring errors.Click “Save Email Settings” when you save the entered information into the option.