12 SpecificationsYASKAWA SIEP C730600 89E PROFINET Technical Manual 53Figure 11.3 Option Installation for CE Compliance: GA500, HV6003. Ground the largest possible surface area of the shield to the metal panel.Use cable clamps if possible.A - Braided shield cableB - Metal panelC - Cable clamp (conductive)Figure 11.4 Ground Area12 Specifications◆ SpecificationsTable 12.1 Option SpecificationsItems SpecificationsModel SI-EP3Option Conformance Passed PROFINET Conformance Class AConnector Type Dual RJ45 8-pin Shielded Twisted Pair Cat 5e cablePhysical Layer Type Isolated Physical Layer TCP Protocol Transformer IsolatedIP Address Setting Programmable from drive keypad or networkCommunication Speed Programmable from drive keypad or network: 10/100 Mbps, auto-negotiate.Number of Connections1 PLC connection1 supervisor connection2 web page connectionsDuplex Mode Half-forced, Auto-negotiate, Full-forcedAddress Startup Mode Static, DHCPAmbient Temperature -10°C - +50°C (14°F - 122°F)Humidity Up to 95% RH (no condensation)Storage Temperature -20°C - +60°C (-4°F - 140°F) allowed for short-term transport of the productArea of UseIndoors and free from:• Oil mist, corrosive gas, flammable gas, and dust• Radioactive materials or flammable materials, including wood• Harmful gas or fluids• Salt• Direct sunlight• Falling foreign objectsAltitude Up to 1000 m (3280 ft)PROFINET FunctionsPROFINET IO with PROFIdrive profileConfigurable I/O in cyclic messagesDrive diagnostic alarmsI&M0