2334 CHAPTER 134: E1 AND T1 CONFIGURATIONQuerying the TrunkCircuits of a Timeslot ora Range of TimeslotsFollow these steps to query the trunk circuits of a timeslot or a range of timeslots:Configuring DigitalLGS SignalingConfiguring the TimeAdjustment FunctionFollow these steps to configure the time adjustment function:n For the delay start-dial, timer first-dial, timer dial-interval, delay, delaysend-dtmf, and timer ring-back commands, refer to “VoIP Overview” on page2243.Querying the TrunkCircuits of a Timeslot ora Range of TimeslotsFollow these steps to query the trunk circuits of a timeslot or a range of timeslots:To do... Use the command... RemarksEnter system view system-view -Enter E1/T1 interface view controller { e1 | t1 } number -Create a TS set for digitalE&M signaling and select astart modetimeslot-set ts-set-numbertimeslot-list timeslots-list signal{ e&m-delay | e&m-immediate |e&m-wink }RequiredEnter digital E&M signalingviewcas ts-set-number -Query the trunk circuits of atimeslot or a range oftimeslotsts query timeslots timeslots-list OptionalTo do... Use the command... RemarksEnter system view system-view -Enter E1/T1 interface view controller { e1 | t1 } number -Create a TS set, enable digitalLGS signaling and set its startmodetimeslot-set ts-set-numbertimeslot-list timeslots-listsignal { fxo-ground |fxs-ground | fxo-loop |fxs-ground | fxs-loop }OptionalEnter voice view voice-setup -Enter voice subscriber lineviewsubscriber-line:ts-set-number-Configure the dial delay delay start-dial value Optional1 second by default.Configure the maximum timewaiting for the subscriber todial the first digittimer first-dial seconds Optional10 seconds by default.Configure the maximuminterval between any twodialed digitstimer dial-interval seconds Optional10 seconds by default.Configure the maximum timethat the calling party waits fora ringback responsetimer ring-back seconds Optional60 seconds by default.To do... Use the command... RemarksEnter system view system-view -