Software Installation and User’s Guide139ICP RAID Console• Select the Build/Rebuild Progress option and press Enter.Whenever an array drive is in the build or rebuild state, you can select Build/RebuildProgress to get progress information and estimates for the required time to build orrebuild.10.5.4.2 Create New Array DriveFrom the Advanced Setup menu, select the Configure Array Drives option and press Enterto display the Select Array Drive menu, then select the Create new Array Drive option andpress Enter.ICPCON lists all logical drives which are free (see Figure 10-88). The selection bar ismoved with the arrow up/down keys and a logical drive is selected/deselected with thespace bar.Figure 10-88. Create New Array DriveFor a striping array (RAID 0, 4, 5, 10), the master drive (indicated by ‘M’) is the firstlogical drive in the array (see Figure 10-88). For a RAID 1 array (mirroring) the masterdrive is the first logical drive in the array that contains the valid data copied to the secondlogical drive.After you press Enter, ICPCON displays a list of possible RAID levels. See Figure 10-89.Then ICPCON prompts you for the stripe size. This is the size of the stripes into which thedata is divided. Valid values are 16KB, 32KB, 64KB or 128KB. The default is 128KB.See Figure 10-90.Figure 10-89. Choose Type