212Software Installation and User’s GuideFibre Channel Features• Use between 8-18 logical drives in your RAID configurations.C.3 SES SupportThis section describes how to change and verify SES status for an FC-enabled ICP RAIDcontroller.C.3.1 SES Status ChangeYou must use ICPCON X-ROM to change SES status for an FC-enabled ICP RAIDcontroller.Note: You can verify SES status from ICPCON or ICP RAID Navigator (see Section C.3.2).1. From ICPCON X-ROM, select the contoller. The Express Setup menu opens.2. Press . The Advanced Setup menu opens.3. From the Advanced Setup menu, select Configure Controller.4. From the Configure Controller menu, select Controller Settings.5. From the Controller Settings menu, select SES Support.6. Press .7. Select “Disabled” or “Enabled.”C.3.2 SES VerificationYou can use ICPCON or ICP RAID Navigator to verify SES status.C.3.2.1. Verifying SES Status in ICPCON1. From ICPCON X-ROM, select the contoller. The Express Setup menu opens.2. Press . The Advanced Setup menu opens.3. From the Advanced Setup menu, select Configure Physical Devices.4. From the Configure Physical Devices menu, select an FCAL hard drive.5. Press . The Configure Disk menu opens.6. Select “Enclosure State” or “Enclosure Slot Configuration.”C.3.2.2. Verifying SES Status in ICP RAID Navigator1. From ICP RAID Navigator, select the controller.2. Open the Physical Configuration view.3. Right-click on the FC-AL drive.4. Select “SES: Enclosure Status” or “SES: Enclosure Configuration.”