Software Installation and User’s Guide187ICP RAID NavigatorUse the last status from the physical drive information to analyze the cause of the drivefailure. Additionally, check for retries and/or reassigns.A drive failure may also be the result of bad or cabling, wrong termination or overheating.Figure 11-150. The Error State11.6 The Statistics WindowFigure 11-151. Statistics Window IconThe statistics window displays the throughput of physical, logical and host drives. Thevertical axis show throughput, the horizontal axis, time. You can add drives by draggingand dropping them from the physical and logical configuration windows into the statisticswindow. To change the layout of the lines, adjust the scales of the axis or remove drivesfrom the statistics windows using the chart menu.Scale the statistics window using the arrow keys. Scale time down/up using the left/rightarrow keys. Scale throughput using the up/down arrow keys.