General Configuration ScreenDLE22-MA,DLE32-MA,DLE23-MA and DLE33-MA User’s Guide 5-472. Use the SPACE bar to toggle the options (DISTRIBUTED orSTAND ALONE) until the desired mode displays.3. Use the arrow keys to highlight the SAVE command, then pressENTER. The warning screen shown in Figure 5-18 displays.4. Use the arrow keys to highlight the YES command and press ENTER.The changes are saved and the module reboots.5.15.11 Configuring the COM PortThe DLE2X-MA and DLE3X-MA COM ports support the followingapplications:• Local Management connections• American Power Conversion Uninterruptible Power Supply (UPS)connectionsTo configure the COM port, proceed as follows:1. Use the arrow keys to highlight the Com field.2. Press the SPACE bar to choose either ENABLED or DISABLED.The COM port must be ENABLED if it will be used for Local! Before altering the COM port settings, ensure that a valid IPaddress is set for the module or chassis. (Refer toSection 5.15.1, Setting the IP Address.) Read this entireCOM port configuration section before changing the settings ofthe COM port.Refer to the Release Notes included with the DLE2X-MA andDLE3X-MA to verify which COM Port applications are currentlysupported.! Do NOT disable or alter the settings of the COM port whileoperating the current Local Management connection through aterminal. Altering the COM port settings disconnects the LocalManagement terminal from the port, and ends the LocalManagement session.