Module Selection ScreenDLE22-MA,DLE32-MA,DLE23-MA and DLE33-MA User’s Guide 5-313. Use the arrow keys to highlight the Source Port field.4. Press the SPACE bar or BACKSPACE one or more times to incrementor decrement the port number displayed in the brackets [n] until theappropriate port number is displayed.5. Use the arrow keys to highlight the Destination Module field.6. Use the SPACE bar or BACKSPACE to step to the appropriatemodule number for the destination module.7. Use the arrow keys to highlight the Destination Port field.8. Use the SPACE bar or BACKSPACE to step to the appropriate portnumber for the destination port.9. Use the arrow keys to highlight the Status field.10. Use the SPACE bar to select either the [ADD] or [DEL] (delete)option. Press ENTER. This adds or deletes the selections made in steps2 and 4 and also updates the screen Source Module, Source Port,Destination Module and Destination Port lists.11. Use the arrow keys to highlight the Errors field.12. Use the SPACE bar to select either the [ON] or [OFF] option andpress ENTER. [ON] forces the source module and port to forwarderrored frames to the destination module(s) and port(s). [OFF] forcesthe errored frames to be dropped before forwarding traffic.13. Use the arrow keys to highlight SAVE at the bottom of the screen.Press ENTER. The message “SAVED OK” is displayed.5.12 MODULE SELECTION SCREENThe Module Selection screen is the access point to Local Management forall modules installed in the DIGITAL MultiSwitch 700 chassis. Byselecting a module, the Module Menu for the selected device displays.Figure 5-14 shows the Module Selection screen.If more than one module and port is to be redirected, repeatsteps 1 through 12 for each additional setting, then go to step13 to save all the new settings at once.