Service Manual February 2017Specifications2 S-80 • S-85 • S-80X Part No. 1259369GTPerformance SpecificationsDrive speed, maximumStowed position,RT tires40 ft / 7.9 - 8.5 sec12.2 m / 7.9 - 8.5 secStowed position,High Flotation tires40 ft / 11 - 13 sec12.2 m / 11 - 13 secRaised or Extended 40 ft / 40 - 45 sec12.2 m / 40 - 45 secBraking distance, maximumHigh range on paved surface 6 ft / 1.8 mGradeability Refer to Operator's ManualBoom function speeds, maximum from platformcontrolsJib Boom up (S-85) 25 - 35 secJib Boom down (S-85) 15 - 25 secBoom up (ANSI, CSA, models) 57 - 65 secBoom up (CE, AS models) 75 - 83 secBoom down (ANSI, CSA, models) 61 - 69 secBoom down (CE, AS models) 75 - 83 secBoom extend 59 - 67 secBoom retract 57 - 65 secTurntable rotate, (360°) fully stowed 95 - 103 secTurntable rotate, (360°) boom raisedor extended210 - 250 secPlatform rotate, 160° 8 - 12 secPlatform level (10° range of motion)ANSI, CSA3 - 5 secPlatform level (10° range of motion)CE, AS20 - 22 secFor operational specifications, refer to theOperator's Manual.Hydraulic Oil SpecificationsHydraulic Fluid SpecificationsGenie specifications require hydraulic oils which aredesigned to give maximum protection to hydraulicsystems, have the ability to perform over a widetemperature range, and the viscosity index shouldexceed 140. They should provide excellent antiwear,oxidation prevention, corrosion inhibition, sealconditioning, and foam and aeration suppressionproperties.Cleanliness level,minimumISO 15/13Water content,maximum250 ppmRecommended Hydraulic FluidHydraulic oil type Chevron Rando HD PremiumViscosity grade 32Viscosity index 200Optional Hydraulic FluidsMineral based Shell Tellus S2 V 32Shell Tellus S2 V 46Shell Tellus S4 VX 32 ShellShell Donax TG (Dexron III)Chevron 5606ABiodegradable Petro Canada Environ MV 46Fire resistant UCON Hydrolube HP-5046Note: Genie specifications require additionalequipment and special installation instructions forthe approved optional fluids. Consult GenieProduct Support before use.Optional fluids may not havethe same hydraulic lifespan andmay result in componentdamage.Note: Extended machine operation can cause thehydraulic fluid temperature to increase beyond it'smaximum allowable range. If the hydraulic fluidtemperature consistently exceeds 200°F / 90°C anoptional oil cooler may be required.