Service Manual February 2017Checklist B Procedures36 S-80 • S-85 • S-80X Part No. 1259369GTB-9Check the Drive Hub Oil Leveland Fastener TorqueGenie specifications require that this procedure beperformed every 250 hours or quarterly, whichevercomes first.Failure to maintain proper drive hub oil levels maycause the machine to perform poorly and continueduse may cause component damage.Drive Hubs:1 Drive the machine to rotate the hub until theplugs are located one on top and the other at90 degrees.1 drive hub plugs2 Remove the plug located at 90 degrees andcheck the oil level.Result: The oil level should be even with thebottom of the plug hole.3 If necessary, remove the top plug and add oiluntil the oil level is even with the bottom of theside plug hole.4 Install the plug(s) into the drive hub.5 Check the torque of the drive hub mountingbolts. Refer to Specifications, MachineSpecifications.6 Repeat this procedure for each drive hub.Turntable rotate drive hubs:1 Remove one of the plugs located on the sideof the hub and check the oil level.Result: The oil level should be even with thebottom of the plug hole.Dual fill port rotator1 motor2 drive hub3 drive hub mounting bolts4 fill ports2 If necessary, add oil until the oil level is evenwith the bottom of the plug hole. Refer toSpecifications, Fluid Capacity Specifications.3 Apply pipe thread sealant to the plug, andinstall the plug in the drive hub.4 Check the torque of the turntable rotate drivehub mounting fasteners. Refer toSpecifications, Machine Specifications.