Service Manual February 2017Checklist A Procedures28 S-80 • S-85 • S-80X Part No. 1259369GTA-12Grease the Turntable RotationBearing and Rotate GearGenie specifications require that this procedure beperformed every 100 hours of operation.Perform this procedure more often if dustyconditions exist.Frequent application of lubrication to the turntablebearing and rotate gear is essential to goodmachine performance and service life. Continueduse of an improperly greased bearing and gear willresult in component damage.1 Locate the grease fitting for the turntablerotate bearing.2 Pump grease into the turntable rotationbearing. Rotate the turntable in increments of4 to 5 inches / 10 to 13 cm at a time and repeatthis step until the entire bearing has beengreased.3 Apply grease to each tooth of the drive gear,located under the turntable.Grease SpecificationChevron Ultra-duty grease, EP NLGI 1 (lithium based)or equivalentA-13Replace the Drive Hub OilDrive hub specifications require that this one-timeprocedure be performed after the first 150 hours ofusage. After this interval, refer to the maintenancechecklist for continued scheduled maintenance.Replacing the drive hub oil is essential for goodmachine performance and service life. Failure toreplace the drive hub oil at yearly intervals maycause the machine to perform poorly and continueduse may result in component damage.1 Refer to Section D Maintenance Procedure,Replace the Drive Hub Oil.