CWS-BA-e-061036F-02-X Automatic reference optimisationFunctionkeyParameterselection Description of functionReference optimisation during input of reference weight by weighing (chpt.. 9.2 )0 Reference optimisation disabled1* Automatic reference optimizationF-02-012 Manual reference optimisation (using ENTER key)Reference optimisation during numeric input of reference weight (chpt.. 9.3 ) or via IDno. (chpt. 9.4 )0 Reference optimisation disabled1* Manual reference optimisation (using ENTER key).This setting is enabled when the setting F-02-01 is not "0".F-02-022 Automatic reference optimisation obeys F-02-01 settingMinimum reference weight (1d = readability, see chpt. 1)0 1/5 dF-02-031* 1/100 dF-02-X summation functionFunctionkeyParameterselection Description of functionAutomatic/manual M+ add-up (chpt.. 11)0* Manual adding-up by pressing the M+ keyF-03-011 Automatic add-up, (positive data only)Selection summation data0* Positive data only (5d and above)1 Positive and negative data (5d and above or -5d and below)F-03-02 +5d +0-M+ not acceptedF-03-02=0+5d-5d+0-M+ not acceptedF-03-02=1