CWS-BA-e-0610 4115 Description of individual functions15.1 ACAI function (automatic counting accuracy improvement = automaticreference optimisation)In order to improve add-up accuracy, theACAI function calculates the referenceweight anew each time new pieces areadded.At every reference optimisation, the ref-erence weight is calculated anew. As theadditional pieces increase the base forthe calculation, the reference also be-comes more exact.3.108Kg 111.000 g28ACAI notes• The ACAI procedure must be carried out after setting the reference weight. Forthis purpose the piece number must still be on the weighing plate.• Do not remove the piece number before the ACAI procedure is complete.• If the pieces remain within the ADAI range, they must not be counted during add-ing.• If you want to have the most accurate add-up results for each different batch ofidentical pieces, use the ADAI each time when starting a count for a new batch.• The ACAI function is set by the factory to manual operation if the reference weightis entered digitally via the keyboard, the ID memory or via PC via serial interface.This can be converted to automatic mode. The ACAI mode during the input of thereference weight via ID or digital input is controlled via function F-02-02 (see chpt.14.2).15.1.1 ACAI automatic modeSetting in menu (chpt..14): F-02-01 = „1“1. Run:Leave the piece number on the weigh-ing plate after setting the referenceweight1.110Kg 111.000 g10