TS-990S170ADJUSTMENTItem ConditionMeasurement AdjustmentSpecifications/RemarksTest-equipment Unit Terminal Unit Parts MethodHF BPF*1• 1.8Mcheck7) Main display f.: 1.800000MHzMode: USBP.AMP: ONSpectrum analyzer settingStart frequency: 0MHzStop frequency: 6MHzTG level: 0dBmTrackinggeneratorSpectrumanalyzerRX(A/2)CN1CN93Check that it is thefrequency responseas shown. 1.705MHz 2.50MHz• 3.5M 8) Main display f.: 3.500000MHzMode: USBP.AMP: ONSpectrum analyzer settingStart frequency: 0MHzStop frequency: 8MHzTG level: 0dBm2.50MHz 4.10MHz• 5M 9) Main display f.: 5.330000MHzMode: USBP.AMP: ONSpectrum analyzer settingStart frequency: 0MHzStop frequency: 10MHzTG level: 0dBm4.10MHz 6.00MHz• 10M 10) Main display f.:10.100000MHzMode: USBP.AMP: ONSpectrum analyzer settingStart frequency: 2MHzStop frequency: 16MHzTG level: 0dBm7.50MHz 10.50MHz• 18M 11) Main display f.:18.100000MHzMode: USBP.AMP: ONSpectrum analyzer settingStart frequency: 8MHzStop frequency: 26MHzTG level: 0dBm14.50MHz 18.50MHz• 24M 12) Main display f.:24.900000MHzMode: USBP.AMP: ONSpectrum analyzer settingStart frequency: 0MHzStop frequency: 50MHzTG level: -10dBm21.50MHz 26.50MHz