TS-990S180ADJUSTMENTItem ConditionMeasurement AdjustmentSpecifications/RemarksTest-equipment Unit Terminal Unit Parts Method18. SUB RX HFBPF• 30k~522k1) Sub display f.: 135kHzMode: USBP.AMP: OFFSpectrum analyzer settingStart frequency: 0MHzStop frequency: 1.2MHzTG level: 0dBmTrackinggeneratorSpectrumanalyzerTX-RX(A/2)CN200CN230Check the waveform.30kHz 522kHz• 522k~~1.705M2) Sub display f.: 525kHzMode: USBP.AMP: OFFSpectrum analyzer settingStart frequency: 0MHzStop frequency: 2.5MHzTG level: 0dBm522kHz 1.705MHz• 1.8M 3) Sub display f.: 1.800000MHzMode: USBP.AMP: OFFSpectrum analyzer settingStart frequency: 0MHzStop frequency: 4MHzTG level: 0dBm1.705MHz 2.50MHz• 3.5M 4) Sub display f.: 3.500000MHzMode: USBP.AMP: OFFSpectrum analyzer settingStart frequency: 0MHzStop frequency: 6MHzTG level: 0dBm2.50MHz 4.10MHz• 5M 5) Sub display f.: 5.300000MHzMode: USBP.AMP: OFFSpectrum analyzer settingStart frequency: 0MHzStop frequency: 12MHzTG level: 0dBm4.10MHz 6.90MHz• 10M 6) Sub display f.: 10.100000MHzMode: USBP.AMP: OFFSpectrum analyzer settingStart frequency: 2MHzStop frequency: 16MHzTG level: 0dBm7.50MHz 10.50MHz