TS-990S190ADJUSTMENTItem ConditionMeasurement AdjustmentSpecifications/RemarksTest-equipment Unit Terminal Unit Parts MethodSUB RX50M SSBS-meter• S92) Menu No.: 58 (50.2MHz,USB)P.AMP: ONFIL/SEL(S): 10M 2.7kHzAGC: MIDSSG f.: 50.201MHzSSG output: -88dBm (8.9μV)SSG RearpanelANT 1 Frontpanel[UP]/[UP-DATE](F5)Set the SSG, pressthe [UP]/[UPDATE](F5) key.• Full scale(Lights upall)3) Menu No.: 59 (50.2MHz,USB)P.AMP: ONFIL/SEL(S): 10M 2.7kHzAGC: MIDSSG f.: 50.201MHzSSG output: -28dBm (8.9mV)56. SUB RX50M FM S-meter• S11) Menu No.: 60 (50.2MHz, FM)SSG f.: 50.200MHzSSG output: –117dBm(0.32μV)MOD: 1kHzDEV: 3kHz• Full scale(Lights upall)2) Menu No.: 61 (50.2MHz, FM)SSG f.: 50.200MHzSSG output: –95dBm(3.98μV)• Full scale2 (Lights upall)3) Menu No.: 62 (50.2MHz, FM)SSG f.: 50.200MHzSSG output: -81dBm(19.9μV)57. SUB RX50M FM SQLthreshold1) Menu No.: 63 (50.2MHz, FM)SSG f.: 50.200MHzSSG output: OFFMOD: 1kHzDEV: 3kHz58. SUB RX50M FM SQLtight1) Menu No.: 64 (50.2MHz, FM)SSG f.: 50.200MHzSSG output: –113dBm(0.501μV)MOD: 1kHzDEV: 3kHz