TS-990S203ADJUSTMENTItem ConditionMeasurement AdjustmentSpecifications/RemarksTest-equipment Unit Terminal Unit Parts Method31. HF PGC• 100W1) Menu No.: 97 (14.1MHz, CW)TransmitPowermeter500W ATTRearpanelANT1 Frontpanel[UP]/[+](F5)or[DOWN]/[-](F4)Adjust the ALCmeter zone to maxi-mum.ALC meter 35 dots• 50W 2) Menu No.: 98 (14.1MHz, CW)Transmit• 25W 3) Menu No.: 99 (14.1MHz, CW)Transmit• 10W 4) Menu No.: 100 (14.1MHz,CW)Transmit• 5W 5) Menu No.: 101 (14.1MHz,CW)Transmit32. FMdeviation• Wide1) Menu No.: 102 (29.1MHz,FM)TransmitPowermeterLineardetector500W ATTRearpanelANT1 Frontpanel[UP]/[+](F5)or[DOWN]/[-](F4)4.2kHzAccording to thelarger +, –.±0.05kHz• Narrow 2) Menu No.: 103 (29.1MHz,FM)Transmit2.1kHzAccording to thelarger +, –.±0.05kHz33. SCOPEgain1) Menu No.: 113 (14.1MHz,CW)TransmitPowermeter500W ATTRearpanelANT1 Frontpanel[[UP]/[UP-DATE](F5)1 push34. Protection• 14M1) Menu No.: 105 (14.1MHz,CW)TransmitUse a cable that is 1m longTS-990 (1m cable)Power meter (Direct connection)150 dummy load150dummyloadThroughtypepowermeterRearpanelANT1 Frontpanel[UP]/[+](F5)or[DOWN]/[-](F4)Set the adjustmentvalue wiithin thelimit of the specifi edpower.80W±2W