TS-990S176ADJUSTMENTItem ConditionMeasurement AdjustmentSpecifications/RemarksTest-equipment Unit Terminal Unit Parts MethodPre-selector• 7M7) Menu No.: 0 (14.2MHz, USB)P.SEL: ONSpectrum analyzer settingCenter f.: 7.1650MHzFrequency span: 400kHzTG level: -10dBmTrackinggeneratorSpectrumanalyzerAcces-sory(B/10)CN401(PREI)CN446(PREO)Frontpanel[UP]/[+](F5) or[DOWN]/[-](F4)Change the adjust-ment values to getthe highest peakpoints as shown.Press the [Apply](F7) key to store theadjustment value.7.1650MHz±20kHz• 10M 8) Menu No.: 0 (14.2MHz, USB)P.SEL: ONSpectrum analyzer settingCenter f.: 10.0650MHzFrequency span: 400kHzTG level: -10dBm10.0650MHz±20kHz• 14M 9) Menu No.: 0 (14.2MHz, USB)P.SEL: ONSpectrum analyzer settingCenter f.: 14.1625MHzFrequency span: 1MHzTG level: -10dBm14.1625MHz±50kHz• 18M 10) Menu No.: 0 (14.2MHz,USB)P.SEL: ONSpectrum analyzer settingCenter f.: 18.1305MHzFrequency span: 2MHzTG level: -10dBm18.1305MHz±100kHz• 21M 11) Menu No.: 0 (14.2MHz,USB)P.SEL: ONSpectrum analyzer settingCenter f.: 21.2250MHzFrequency span: 2MHzTG level: -10dBm21.2250MHz±100kHz• 24M 12) Menu No.: 0 (14.2MHz,USB)P.SEL: ONSpectrum analyzer settingCenter f.: 24.9150MHzFrequency span: 2MHzTG level: -10dBm24.9150MHz±100kHz• 28M 13) Menu No.: 0 (14.2MHz,USB)P.SEL: ONSpectrum analyzer settingCenter f.: 28.8250MHzFrequency span: 4MHzTG level: -10dBm28.8250MHz±200kHz