TS-990S188ADJUSTMENTItem ConditionMeasurement AdjustmentSpecifications/RemarksTest-equipment Unit Terminal Unit Parts Method46. SUB RXAGC startlevel(11M/2.7kHz)1) Menu No.: 42 (14.2MHz,USB)P.AMP: ONFIL/SEL(S): 11M 2.7kHzAGC: OFFSSG f.: 14.201MHzSSG output: –110dBm(0.707μV)SSG RearpanelANT 1 Frontpanel[UP]/[+](F5) or[DOWN]/[-](F4)Using the [UP]/[+](F5) or [DOWN]/[-](F4) key, adjust tothe point when “A/Ddata” displays “1” forthe fi rst time.47. SUB RXAGC startlevel(11M 500Hz)1) Menu No.: 43 (14.2MHz,USB)P.AMP: ONFIL/SEL(S): 11M 500HzAGC: OFFSSG f.: 14.201MHzSSG output: –110dBm(0.707μV)48. SUB RXAGC gaincurve1) Menu No.: 46 (14.2MHz,USB)P.AMP: ONFIL/SEL(S): 11M 2.7kHzAGC: MIDSSG f.: 14.201MHzSSG output: –55dBm(0.398mV)[UP]/[UP-DATE](F5)Set the SSG, pressthe [UP]/[UPDATE](F5) key.49. SUB RX HFSSB S-meter• S11) Menu No.: 47 (14.2MHz,USB)P.AMP: ONFIL/SEL(S): 11M 2.7kHzAGC: MIDSSG f.: 14.201MHzSSG output: -107dBm (1μV)• S9 2) Menu No.: 48 (14.2MHz,USB)P.AMP: ONFIL/SEL(S): 11M 2.7kHzAGC: MIDSSG f.: 14.201MHzSSG output: -81dBm(19.9μV)• Full scale(Lights upall)3) Menu No.: 49 (14.2MHz,USB)P.AMP: ONFIL/SEL(S): 11M 2.7kHzAGC: MIDSSG f.: 14.201MHzSSG output: -21dBm(19.9mV)50. SUB RX HFFM S-meter• S11) Menu No.: 50 (29.2MHz, FM)SSG f.: 29.200MHzSSG output: –117dBm(0.32μV)MOD: 1kHzDEV: 3kHz