4 - Language Dictionary[SOURce:]CURRent:TLEVelChannel SpecificThis command specifies the transient level of the input current. The transient function switches betweenthe immediate setting and the transient level. Refer to Table 4-1 for model-specific programming ranges.Command Syntax [SOURce:]CURRent:TLEVel Parameters 0 through MAX | MINimum | MAXimumUnit A (amperes)*RST Value MAXimumExamples CURR:TLEV 5 CURR:TLEV .5Query Syntax [SOURce:]CURRent:TLEVel?Returned Parameters Related Commands CURR:[SOURce:]CURRent:TRIGgeredChannel SpecificThis command sets the current level that will become active when the next trigger occurs.Command Syntax [SOURce:]CURRent[:LEVel]:TRIGgered[:AMPLitude] Parameters refer to Specifications Table in User’s GuideUnit A (amperes)*RST Value MINimumExamples CURR:TRIG 15Query Syntax [SOURce:]CURRent:TRIG?Returned Parameters (if the trigger level is not programmed, the immediatelevel is returned)Related Commands CURR: CURR:MODE[SOURce:]FUNCtion[SOURce:]MODEChannel SpecificThese equivalent commands select the input regulation mode of the electronic load.CURRent constant current modeRESistance constant resistance modeVOLTage constant voltage modeCommand Syntax [SOURce:]FUNCtion [SOURce:]MODE Parameters CURRent | RESistance | VOLTage*RST Value CURRentExamples FUNC RES MODE VOLTQuery Syntax [SOURce:]FUNCtion? [SOURce:]MODE?Returned Parameters Related Commands FUNC MODE FUNC TRIG VOLTEquivalent Commands MODE:CURR MODE:RES MODE:VOLT64