4 - Language DictionaryTrigger CommandsTrigger commands controls the triggering of the electronic load. Chapter 3 under "Triggering Changes"provides an explanation of the Trigger System.See also [SOURce:]CURRent:TRIGgered, [SOURce:]RESistance:TRIGgered, and[SOURce:]VOLTage:TRIGgered in the Input Commands section.NOTE: The list and measurement commands must first be enabled using the INITiate commandsor no action due to triggering will occur. This does not apply to transient triggers.ABORtThis command resets the list and measurement trigger systems to the Idle state. Any list or measurementthat is in progress is immediately aborted. ABORt also resets the WTG bit in the Operation ConditionStatus register (see chapter 3 under “Programming the Status Registers”). ABORt is executed at powerturn-on and upon execution of *RCL, RST, or any implied abort command (see List Commands).NOTE: If INITiate:CONTinuous ON has been programmed, the trigger system initiates itselfimmediately after ABORt, thereby setting the WTG bit.Command Syntax ABORtParameters NoneExamples ABORRelated Commands INIT *RST *TRG TRIGINITiate:SEQuenceINITiate:NAMEThese equivalent commands prepare the list for the execution of the next trigger. These commands arenot channel specific, they apply to the entire mainframe. If the trigger system is not in the Idle state, theyare ignored. INITiate:SEQuence references the list sequence by a number, while INITiate:NAMEreferences the list sequence by the name LIST.Sequence Number Sequence Name Description1 (the default) LIST List trigger sequenceCommand Syntax INITiate[:IMMediate]:SEQuence[ 1 ]INITiate[:IMMediate]:NAME LISTParameters For INIT:NAME: LISTExamples INIT:SEQ1 INIT:NAME LISTRelated Commands ABOR INIT:CONT TRIG *TRGINITiate:SEQuence2INITiate:NAMEThese equivalent commands prepare the measurement system to take a measurement on the nexttrigger. These commands are not channel specific, they apply to the entire mainframe. If the triggersystem is not in the Idle state, they are ignored. INITiate:SEQuence references the measurementsequence by a number, while INITiate:NAME references the measurement sequence by the nameACQuire.Sequence Number Sequence Name Description2 ACQuire Measurement acquire trigger sequence96