4 - Language Dictionary[SOURce:]LIST:CURRent:SLEW:NEGativeChannel SpecificThis command sets the negative current slew rate for each step. MAXimum sets the slew to its fastestpossible rate. MINimum sets the slew to its slowest rate.Command Syntax [SOURce:]LIST:CURRent:SLEW:NEGative {,}Parameters 0 to 9.9E37 | MAXimum | MINimumUnit A (amperes per second)*RST Value MAXimumExamples LIST:CURR:SLEW:NEG 50 LIST:CURR:SLEW:NEG MAXQuery Syntax [SOURce:]LIST:CURRent:SLEW:NEGative?Returned Parameters {,}Related Commands CURR:SLEW:NEG[SOURce:]LIST:CURRent:SLEW:POSitiveChannel SpecificThis command sets the positive current slew rate for each step. MAXimum sets the slew to its fastestpossible rate. MINimum sets the slew to its slowest rate.Command Syntax [SOURce:]LIST:CURRent:SLEW:POSitive {,}Parameters 0 to 9.9E37 | MAXimum | MINimumUnit A (amperes per second)*RST Value MAXimumExamples LIST:CURR:SLEW:POS 50 LIST:CURR:SLEW:POS MAXQuery Syntax [SOURce:]LIST:CURRent:SLEW:POSitive?Returned Parameters {,}Related Commands CURR:SLEW:POS[SOURce:]LIST:CURRent:TLEVel[SOURce:]LIST:CURRent:TLEVel:POINts?Channel SpecificThis command specifies the transient current level for each step. The transient function switches betweenthe immediate setting and the transient level. LIST:CURRent:TLEVel:POINts? returns the number ofpoints programmed.Command Syntax [SOURce:]LIST:CURRent:TLEVel {,}Parameters refer to Specifications Table in User’s GuideUnit A (amperes)*RST Value MAXimumExamples LIST:CURR:TLEV 5 LIST:CURR:TLEV .5Query Syntax [SOURce:]LIST:CURRent:TLEVel?[SOURce:]LIST:CURRent:TLEVel:POINts?Returned Parameters {,}Related Commands CURR:TLEV80