Troubleshooting 8-15Errorcode Error message Recommended Action0B74 The error occurred during voltage sensorreading.0B75 System voltage out of the range.Contact your service representative.0B80 BMC Memory Test Failed.0B81 BMC Firmware Code Area CRC check failed.0B82 BMC core Hardware failure.0B83 BMC 1BF or 0BF check failed.Turn off the power once and then on again tostart the server. If the error cannot becorrected, contact your service representative.0B8A BMC SEL area full. Start SETUP and select [Server] - [Event LogConfiguration] - [Clear All Error Logs] andpress Enter to clear event logs.0B8B BMC progress check timeout.0B8C BMC command access failed.0B8D Could not redirect the console - BMC Busy -0B8E Could not redirect the console - BMC Error -0B8F Could not redirect the console - BMCParameter Error -0B90 BMC Platform Information Area corrupted.0B91 BMC update firmware corrupted.Turn off the power once and then on again tostart the server. If the error cannot becorrected, contact your service representative.0B92 Internal Use Area of BMC FRU corrupted. This is not a fatal error. Turn off the poweronce and then on again to restart the server. Ifthe error cannot be corrected, contact yourservice representative.0B93 BMC SDR Repository empty. Turn off the power once and then on again torestart the server. If the error cannot becorrected, contact your service representative.0B94 IPMB signal lines do not respond. This is not a fatal error. Turn off the poweronce and then on again to restart the server. Ifthe error cannot be corrected, contact yourservice representative.0B95 BMC FRU device failure. This is not a fatal error. Turn off the poweronce and then on again to restart the server. Ifthe error cannot be corrected, contact yourservice representative.0B96 BMC SDR Repository failure.0B97 BMC SEL device failure.0B98 BMC RAM test error.0B99 BMC Fatal hardware error.Turn off the power once and then on again tostart the server. If the error cannot becorrected, contact your service representative.0B9A BMC not responding. Update the RMC firmware. If the error cannotbe corrected, contact your servicerepresentative.0B9B Private I2C bus not responding.0B9C BMC internal exception.0B9D BMC A/D timeout error.0B9E SDR repository corrupt.0B9F SEL corrupt.Turn off the power once and then on again tostart the server. If the error cannot becorrected, contact your service representative.