Upgrading Your Server 9-296. Make the component side of the board face the bottom of the server, put the rear panel ofthe board on the frame spring securely, and push the board so that the board connectionport is certainly connected to the slot.For a long-sized board, align the board with the groove of the guide rail on the front of theserver and then connect the board to the slot.IMPORTANT: If the board cannot be installed well, remove the boardonce and then install it again. Note that adding an excess force to theboard may cause it to be damaged.7. Install the duct cover removed in Step 4, and secure it with a setscrew.8. Install the left side cover removed in Step 3.9. Turn on the power of the server. Make sure that no error message appears in the POST.If an error message appears, write down the message and contact your servicerepresentative for the maintenance.10. Start the BIOS Setup Utility to set the "Reset Configuration Data" in the "Advanced"menu to "Yes."This is required to update the hardware configuration information. See Chapter 4 fordetails.Frame spring portionGrooves for guide railPCI guide rail