Manual Operation (Home Return)11-1211.3.2 Precautions on Programming Precautions on programming• If any value such as an acceleration time, deceleration time or target speed is out of thespecified range, a setting value error occurs at the time of start.• Unit memory numbers allocated to flags and start requests vary depending on axis numbers.• The specified slot number varies depending on the installation position of the unit. Operation at over limit input (Limit is valid)Condition Direction Limit status OperationWhen Home returnoperation isexecutedForward Over limit input (+): ON ExecutableOver limit input (-): ON ExecutableReverse Over limit input (+): ON ExecutableOver limit input (-): ON ExecutableDuring Homereturn operationForward Over limit input (+): ON Automatic reverse operaitonReverse Over limit input (-): ON Automatic reverse operaiton