Specifications15-5615.8.2 Sychronous Control Setting Area●: Available, -: Not availableAxis no.Unitmemoryno. (Hex)Name Default Description R W1 UM 63F40synchronousmaster axisselectionH0Set the synchronous master axis for each axis.Value SettingH 0000 U0 The target axis is the masteraxis.H 0001 U1 Axis 1H 0002 U2 Axis 2----- ----- -----H 0010 U16 Axis 16----- ----- -----H 0020 U32 Axis 32----- ----- -----H 0040 U64 Axis 64H 0041 U65 Virtual axis 1----- ----- -----H 0060 U96 Virtual axis 32Any other settings will be errors. 1 UM 63F41SynchronousoutputfunctionselectionH0Set the synchronous function for each axis.bit Name Description0 Electronic gearoperation setting0: Not use1: Use1 Clutch operationsetting2 Electronic operationsetting15-3 Area reserved forsystem - 1 UM 63F42Synchronousslave singledecelerationstopdecelerationmethodH0bit Name Description0 Not used1 Deceleration method 0: Linear1:-15-3 Area reserved forsystem - 1 UM 63F43Synchronousslave singledecelerationstopdecelerationtimeU100Set the deceleration time when performing thedeceleration stop during the synchronous operation.Range: 0 to 10,000 [ms]Any other settings will be errors. 1 UM 63F44-UM 63F4FReserved forsystem - - - -(Note): The above table shows the unit memory numbers of axis number 1. For details of the whole configuration,refer to "15.8.1 Configuration of Synchronous Control Setting Area".