Specifications15-2615.5.2 Setting Parameter Control Area●: Available, -: Not availableAxis no.Unitmemoryno. (Hex)Name Default Description R W- UM 00280-UM 00281Number ofwriting toFROMU0Announces the number of writing the positioningparameters and data in the unit memory intoFROM. -- UM 00282 Reservedfor system - - - -- UM 00283 FROM writeresult H0FROM writing in progress : H5555FROM writing ended normally : H0FROM writing ended abnormally : HFFFFFROM writing by CMI in progress: HAAAA -1 UM 00284Recalculation startingtablenumberU1This is used to rewrite positioning data using auser program.Reconstructs the positioning data which startswith the table number specified in this areawhen the recalculation request (Y7) turns on.Range: 1-1000 1 UM 00285Recalculation startingtable sizeU0Reconstructs the positioning data of the tablesize specified in this area when the recalculationrequest (Y7) turns on.Range:1-500 (2-64Virtual 1-32)UM 00286-UM 00343The following areas are allocated to each axis. Recalculation starting table number: 1 word Recalculation starting table size: 1 word - UM 00344-UM 0037FReservedfor system - - - -15.5.3 Operation Speed Rate Area●: Available, -: Not availableAxis no.Unitmemoryno. (Hex)Name Default Description R W1 UM 00380 Operationspeed rate U1All operations relating to axes (positioning, JOGoperation, home return) can be performed at thespecified rate.Range:0-500 [%] (For single axis control)Range:0-200 [%] (For interpolation control) (2-64Virtual 1-32)UM 00381-UM 003DFThe following areas are allocated to each axis. Operation speed rate: 1 word - UM 003E0-UM 003FFReservedfor system - - - -