2. Object index Interbus-S622.11.7 CAM_MEM_PSpecial command for COMPAX XX70.Set and read curve memory pointer.Object DescriptionIndex 0x5fcaSymbol CAM_MEM_P Length 2 Access groups 0Object code Simple var. Password 0Data type Unsigned16 Access rights Read/write all PD Map Not possibleData DescriptionData format Binary Unit Curve memory numberValue range 1 ... 5460 Resolution 12.11.8 CAM_MEMSpecial command for COMPAX XX70.Read and write the curve memory.The curve memory number is defined by the current value of the curve memory pointer (CAM_MEM_P).The curve memory pointer is automatically incremented after this object is accessed.Object DescriptionIndex 0x5fcbSymbol CAM_MEM Length 3 Access groups 0Object code Simple var. Password 0Data type Octet string Access rights Read/write all PD Map Not possibleData DescriptionData byte 1 2 3Meaning Record memory contentsAssignment MSB ... LSB2.11.9 VXEnter or read COMPAX variable.The corresponding variable is selected using the Sub-index (Sub-index = variable No.).Sub-index = 40 addresses variable 0 of the COMPAX, with which all variables can be set to the same value.Object DescriptionIndex 0x5fcdSymbol VX Length 4 Access groups 0Object code Array Elements 40 Password 0Data type Integer32 Access rights Read/write all PD Map Not possible