Parker Hauser COMPAX 10XXSL Series manuals
Hauser COMPAX 10XXSL Series
Table of contents
- Table Of Contents
- Addressing
- PDU Length
- Selectable Data Channels
- Bus – Setting using the front cover
- Data types
- Communication objects: Overview sorted by Symbol
- Communication objects: Overview sorted by Index
- Device identification
- S31_S39
- Control
- STEUERBYTE
- CPX_STW
- CPX_ZSW
- STEUERWORT
- Pop-up message processing
- COMMAND
- Diagnosis
- S23_S26
- Torque, current, voltage
- MOMENT_IST
- ZWK_SPG
- Positioning
- POSR
- LAGE_IST
- REALNULL
- POS_FENSTER
- POLARITAET
- CAM_CMD
- WAITPOSR
- SPEED
- POSR0SPEED
- PRXSDYALZ
- DREHZAHLMAX
- VERF_GESCHW
- GESCHW_IST
- Acceleration
- ACCEL_NEG
- RAMPE_NEG
- RAMPE_REF
- Inputs/outputs
- OUTPUT
- POSROUTPUTP
- Programming
- GOTO
- START_N_GO
- CAM_MEM_P
- OBJECT_REQ and OBJECT_RSP for 8 byte process data channel
- OBJECT_REQ
- Process data control
- PED_Steuerung
- PE_SELECT
- PA_SELECT
- PA_ENABLE
Hauser COMPAX 10XXSL Series
Table of contents
- Table Of Contents
- Table Of Contents
- General
- CAN-Bus components
- Bus setting via front panel
- Data types
- Object types
- Object list
- General objects
- Number of PDOs
- Synchronization window length
- Node number (address, node ID)
- Node guarding (node guarding)
- Emergency
- Service data objects
- Server SDO2 parameters
- Transmission of process data to COMPAX
- Communication parameters for receiving PDO2 (R-PDO2)
- Mapping-Parameter receiving PDO1 (R PDO1)
- R-PDO control
- Reading process data from COMPAX
- Communication parameters for transmission PDO2 (T-PDO2)
- Mapping parameters for transmission PDO1 (T-PDO1)
- Mapping parameters for transmission PDO2 (T-PDO2)
- Control
- Control byte
- COMPAX control word
- CPX_ZSW
- Status word
- Control commands
- COMPAX commands
- Diagnostics
- Status S11
- Status S30
- Error
- Torque, power, voltage
- Status S5
- Status S7_S8
- Positioning
- Status S2
- Limits
- Status S3
- Traverse rate and set point position default
- Speed
- Speed step profiling
- Maximum motor speed
- Status S4
- Acceleration
- Time specification for the braking process
- Inputs/outputs
- OUTPUT_WORD
- OUTPUT_MASK
- OUTPUT
- Programming
- Goto
- Assign current position in record N
- COMPAX XX50 commands
- COMPAX XX70 commands
- Device Profile DSP 402
- CANopen COMPAX parameter
- Overview: manufacturer-specific objects
- Objects sorted by command
- Index
Related products