SAMSUNG MMC PROGRAMSCOMBINED SYSTEMS PROGRAMMING MANUAL FEBRUARY 2004MMC 601 (Page 2 of 3)UCD GROUPSMaximum number of UCD groups that can be programmed is:DCS 10, created from last 10 station groups (520–529)CI 10, created from any station group (501–529)CII 5, created from the last 10 station groups (510–519)816 3, created from the last 3 station groups (507–509)iDCS100 10, created from any groupiDCS500(M) 10, created from any groupiDCS500(L) 20, created from any groupOS500 (S/M) 20, created from any groupOS500 (L) 20, created from any groupOptions for UCD groups are set in MMC 607.RING MODES0 SEQUENTIAL The first idle station listed in the group will ring. If the first isbusy, the next idle station will ring.1 DISTRIBUTE The first call will ring the first station listed in the group. Thenext call will ring the next station listed in the group.2 UNCONDITIONAL All the stations listed in the group will ring. (Busy stationswill receive off-hook ring, if set in MMC 300.) The maximumnumber of stations allowed to ring unconditionally for agroup is: DCS=32, Compact II=10, 816=16, 408/408i=8,iDCS=32, OS500=32Note: When a group is called, or a caller is transferred to a group, ringback is sent to the caller.Calls to a group do not follow the call forwarding instructions of any stations in the group.FEATURE KEY0 TYPE Group type1 RING Ring mode2 OVERFLOW Timer for overflow to ‘Next Port’3 GROUP TRANSFER Timer for recall of calls transferred to group4 NEXT PORT Overflow port (station, group, common bell, ring overpage)5 MEMBER Members of group (e.g. station numbers)6 NEXT HUNT Timer for ringing a station before hunting for nextmember 17 GROUP BUSY If set ON, generates busy tone when all station groupmembers of Sequential or Distribute ring groups arebusy 2 (refer to option SGR INC BUSY in MMC 210)8 GROUP AUTO ANSWER If set ON, stations will Auto Answer calls to the groupNote:1 iDCS500 ‘L’ and OS500 systems only2 iDCS and OS500 systems only