SAMSUNG MMC PROGRAMSCOMBINED SYSTEMS PROGRAMMING MANUAL FEBRUARY 2004MMC 851 (Page 5 of 5)ALM CODE ALARM DEFINITIONMNF06 Trunk DisconnectOut of service trunk detected via seizure of trunk. Externalseizure test.Alarm Data = Cabinet, Slot, Port (Cx-Syy-Pzz)MNF07 Trunk ConnectOut of service trunk recovered via seizure of trunk Externalseizure test.Alarm Data = Cabinet, Slot, Port (Cx-Syy-Pzz)MNF08 SIO TxQ Over SIO Tx Queue full error has occurred in the MCP.Alarm Data = SIO number (SIO:x)MNF09 SIO TxQ Under SIO Tx Queue under error has occurred in the MCP.Alarm Data = SIO number (SIO:x)MNF10 E1 Out Of Srv E1 Digital line status has been changed to out of service.Alarm Data = Cabinet, Slot (Cx-Syy)MNF11 E1 In Service E1 Digital line has been restored to normal service.Alarm Data = Cabinet,Slot (Cx-Syy)MNF12 SIO Out IO port has lost DTRAlarm Data = SIO number (SIO:x)MNF13 SIO In IO port has regained DTR.Alarm Data = SIO 1 through 3MNF14 TODC Error Time of Day Clock in the MCP in error.MNF15 TSW Over AlarmTSW has been requested to exceed the capacity of availabletime slots. Maximum 192 per cabinet.Alarm Data = Cabinet, Slot (Cx-Syy)MNF16 PSU AlarmIndicates there are over 56 ports in a cabinet with a single PSUand more power is required.Alarm Data = Cabinet, Slot (Cx-Syy)MNF17 PSU Alarm RecA second PSU has been recognised when added after alarmcondition of:Alarm Data = Cabinet, Slot (Cx-Syy)MNF18 SLI FaultAn SLI card has been detected as out of service via an internalCODEC test.Alarm Data = Cabinet, Slot, Port (Cx-Syy-Pzz)MNF19 SLI RecoveryAn SLI card detected as out of service has been detected asrecovered and is in service via internal CODEC test.Alarm Data = Cabinet, Slot, Port (Cx-Syy-Pzz)MNF20 PSUB Alarm Indicates there are over 120 ports in a cabinet with two PSUs.Alarm Data = Cabinet, Slot (Cx-Syy)MNF21 DSS Alarm System capacity of 64-button DSS modules has been exceeded.MNF22 Phone Disconnect Indicates the keyset is disconnected.Alarm Data = Cabinet, Slot, Port (Cx-Syy-Pzz)MNF23 Phone Connect Indicates the keyset is connected.Alarm Data = Cabinet, Slot, Port (Cx-Syy-Pzz)MNF24 NOT USED FUTURE USEMNF25 NOT USED FUTURE USEMNF26 SIO RxQ Over SIO Rx Queue full error has occurred in the MCP.Alarm Data = SIO number (SIO:x)MNF27 SIO RxQ Under SIO Rx Queue under error has occurred in the MCP.Alarm Data = SIO number (SIO:x)