SAMSUNG MMC PROGRAMSCOMBINED SYSTEMS PROGRAMMING MANUAL FEBRUARY 2004MMC 205 (Page 1 of 1)MMC: 205 ASSIGN LOUD BELLFOR: DCS CII 816 408i 408 iDCS100 iDCS500 OS500Purpose: Designates the station that controls the loud bell ring output. This output de-pends on your system, as follows.DCS Trunk A card. Each Trunk A card has one loud bell output; theseoutputs are given a Directory Number of 3901–3920 as a defaultvalue to enable them to be assigned.Compact II Misc card (assigned in MMC 219, Common Relay Service Type).816 and 408/408i Base board (assigned in MMC 219, Common Relay Service Type).iDCS500 Misc card. Each Misc card has one loud bell output; these outputsare given a Directory Number of 390x as a default value to enablethem to be assigned.iDCS100 Misc card (assigned in MMC 219, Common Relay Service Type).OS500 Misc card. Each Misc card has one loud bell output; these outputsare given a Directory Number of 3995 (‘L’) or 2995 (‘S’ & ‘M’) as adefault value to enable them to be assigned.The loud bell will follow the ring cadence of the designated station. Only a station can beassigned to control the loud bell; a station group cannot be assigned.ACTION DISPLAY1. Open programming and select 205Display shows current setting [361] LOUD BELLRING PAIR : NONE2. Dial loud bell number (e.g., 362)ORPress VOLUME keys to scroll through loud bellnumbers and press RIGHT soft key to move thecursor[362] LOUD BELLRING PAIR : NONE3. Enter station number (e.g., 201)ORPress VOLUME keys to make selection andpress RIGHT soft key to return to step 2[362] LOUD BELLRING PAIR :2014. Press Transfer/TRSF to store and exitORPress SPEAKER to store and advance to next MMCDefault Data: NONE (Unassigned)Related Items: MMC 219 Common Relay Service Type