5.6 Copy Function Related Displaysu Tasks, Errors, and TroubleshootingThe table below lists the messages and errors that may appear when using the Copy function.When executing the tasks offered by the Copy function, the operator will indicate the task being performed. When an erroroccurs, a code appears on the operator to indicate the error. Note that errors related to the Copy function do not trigger a multi-function output terminal that has been set up to close when a fault or alarm occurs. To clear an error, simply press any key onthe operator and the error display will disappear.Table 5.6 lists the corrective action that can be taken when an error occurs.Note: 1. Whenever using the copy function, the drive should be fully stopped.2. The drive will not accept a Run command while the Copy function is being executed.3. Parameters can only be saved to a drive when the voltage class, capacity, control mode, and software version match.Table 5.6 Copy Function Task and Error DisplaysDigital Operator Display TaskCoPy Writing Parameter Settings (flashing)CPEr Control Mode MismatchCPyE Error Writing DataCSEr Copy Unit ErrordFPS Drive Model MismatchEnd Task CompleteiFEr Communication ErrorndAT Model, Voltage Class, Capacity MismatchrdEr Error Reading DatarEAd Reading Parameter Settings (flashing)vAEr Voltage Class, Capacity MismatchvFyE Parameter settings in the drive and those saved to the copy function are not the samevrFy Comparing Parameter Settings (flashing)u Fault Reset MethodsWhen a fault occurs, the cause of the fault must be removed and the drive must be restarted. The table below lists the differentways to restart the drive.After the Fault Occurs ProcedureFix the cause of the fault, restart the drive, andreset the fault Press on the digital operator. LOREF2F1ESCRUN STOPENTERRESETRESET- MODE -oCOvercurrentDRVFWD RESETResetting via Fault Reset Digital Input S4Close then open the fault signal digital input viaterminal S4. S4 is set for “Fault Reset” as default(H1-04 = 14).Fault Reset SwitchDriveS4 Fault Reset Digital InputSC Digital Input CommonTurn off the main power supply if the above methods do not reset the fault. Reapply power after thedigital operator display has turned off.ONOFF21Note: If the Run command is present, the drive will disregard any attempts to reset the fault. Remove the Run command before attempting to clear afault situation.5.6 Copy Function Related Displays148 YASKAWA ELECTRIC TOEP C710616 41B YASKAWA AC Drive - A1000 Quick Start Guide