Model NumberCIMR-AoHeavy Duty Normal DutyRated Amps(A)Heatsink Loss(W)Interior UnitLoss (W) Total Loss (W) Rated Amps(A) <3>Heatsink Loss(W)Interior UnitLoss (W) Total Loss (W)4A0139 112 <1> 908 416 1325 139 1215 534 17494A0165 150 <2> 1340 580 1920 165 1557 668 22244A0208 180 <2> 1771 541 2313 208 1800 607 24084A0250 216 <2> 2360 715 3075 250 2379 803 31824A0296 260 <2> 2391 787 3178 296 2448 905 33534A0362 304 <2> 3075 985 4060 362 3168 1130 42984A0414 370 <2> 3578 1164 4742 414 3443 1295 47384A0515 450 <3> 3972 1386 5358 515 4850 1668 65184A0675 605 <3> 4191 1685 5875 675 4861 2037 68984A0930 810 <3> 6912 2455 9367 930 8476 2952 114284A1200 1090 <3> 7626 3155 10781 1200 8572 3612 12184<1> Value assumes the carrier frequency is set to 8 kHz or less.<2> Value assumes the carrier frequency is set to 5 kHz or less.<3> Value assumes the carrier frequency is set to 2 kHz.Table A.12 Watt Loss Three-Phase 600 V Class Three-Phase ModelsModel NumberCIMR-AoNormal Duty Heavy DutyRated Amps(A) <1>Heatsink Loss(W)Interior UnitLoss (W) Total Loss (W) Rated Amps(A) <2>Heatsink Loss(W)Interior UnitLoss (W) Total Loss (W)5A0003 2.7 21.5 23.3 44.8 1.7 28.9 19.8 48.75A0004 3.9 27.5 33.6 61.1 3.5 54.3 27.6 81.95A0006 6.1 28.1 43.7 71.8 4.1 53.0 27.0 80.05A0009 9.0 43.4 68.9 112.3 6.3 78.7 36.4 115.15A0011 11 56.1 88.0 144.0 9.8 110.9 49.5 160.35A0017 17 96.6 146.7 243.2 12.5 144.7 67.5 212.25A0022 22 99.4 178.3 277.7 17 203.8 81.1 284.85A0027 27 132.1 227.2 359.3 22 267.2 113.8 381.15A0032 32 141.6 279.9 421.5 27 332.9 132.2 465.15A0041 41 330.8 136.2 467.0 32 405.9 127.6 533.55A0052 52 427.8 166.2 594.0 41 527.2 161.4 688.55A0062 62 791.2 279.0 1070.2 52 1271.5 335.0 1606.55A0077 77 959.1 329.4 1288.6 62 1457.0 379.5 1836.55A0099 99 1253.2 411.7 1664.9 77 1267.0 352.0 1619.0<1> These values assume the carrier frequency is set to 2 kHz.<2> These values assume the carrier frequency is set to 8 kHz or less.A.4 Drive Watt Loss Data174 YASKAWA ELECTRIC TOEP C710616 41B YASKAWA AC Drive - A1000 Quick Start Guide