A.2 Power Ratingsu Three-Phase 200 V Class Drive Models CIMR-Ao2A0004 to 2A0030Table A.2 Power Ratings (Three-Phase 200 V Class)Item SpecificationCIMR-Ao2A 0004 0006 0008 0010 0012 0018 0021 0030Maximum Applicable MotorCapacity (HP) <1>ND Rating 0.75 1 2 3 3 5 7.5 10HD Rating 0.75 1 2 2 3 3 5 7.5InputInput Current (A) <2> ND Rating 3.9 7.3 8.8 10.8 13.9 18.5 24 37HD Rating 2.9 5.8 7 7.5 11 15.6 18.9 28Rated VoltageRated Frequency Three-phase 200 to 240 Vac 50/60 Hz/270 to 340 Vdc <3>Allowable Voltage Fluctuation -15 to 10%Allowable Frequency Fluctuation ±5%Input Power (kVA) ND Rating 2.2 3.1 4.1 5.8 7.8 9.5 14 18HD Rating 1.3 2.2 3.1 4.1 5.8 7.8 9.5 14OutputRated Output Capacity(kVA) <4>ND Rating <5> 1.3 2.3 3 3.7 4.6 6.7 8 11.4HD Rating 1.2<6>1.9<6>2.6<6>3<6>4.2<6>5.3<6>6.7<6>9.5<6>Rated Output Current (A)ND Rating <5> 3.5 6 8 9.6 12 17.5 21 30HD Rating 3.2<6>5<6>6.9<6>8<6>11<6>14<6>17.5<6>25<6>Overload Tolerance ND Rating: 120% of rated output current for 60 sHD Rating: 150% of rated output current for 60 s(Derating may be required for applications that start and stop frequently)Carrier Frequency User adjustable between 1 and 15 kHzMaximum Output Voltage (V) Three-phase 200 to 240 V (proportional to input voltage)Maximum Output Frequency (Hz) 400 Hz (user-set)<1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater thanthe motor current. Select the appropriate capacity drive if operating the motor continuously above motor nameplate current.<2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiringconnections, and power supply impedance.<3> DC is not available for UL/CE standards.<4> Rated motor capacity is calculated with a rated output voltage of 220 V.<5> Carrier frequency is set to 2 kHz. Current derating is required in order to raise the carrier frequency.<6> Carrier frequency can be increased to 8 kHz while keeping this current derating. Higher carrier frequency settings require derating..A.2 Power RatingsYASKAWA ELECTRIC TOEP C710616 41B YASKAWA AC Drive - A1000 Quick Start Guide 163A Specifications