B.7 H Parameters: Multi-Function TerminalsH parameters assign functions to the multi-function input and output terminals.u H1: Multi-Function Digital InputsNo.(Addr.Hex) Name Description Values PageH1-01(438)Multi-Function Digital InputTerminal S1 FunctionSelectionAssigns a function to the multi-function digital inputs.Refer to pages 205 to 208 for descriptions of setting values.Note: Set unused terminals to F.Default: 40 (F) <1>Min.: 1Max.: 9F104H1-02(439)Multi-Function Digital InputTerminal S2 FunctionSelectionAssigns a function to the multi-function digital inputs.Refer to pages 205 to 208 for descriptions of setting values.Note: Set unused terminals to F.Default: 41 (F) <1>Min.: 1Max.: 9F104H1-03(400)Multi-Function Digital InputTerminal S3 FunctionSelectionAssigns a function to the multi-function digital inputs.Refer to pages 205 to 208 for descriptions of setting values.Note: Set unused terminals to F.Default: 24Min.: 0Max.: 9F 104H1-04(401)Multi-Function Digital InputTerminal S4 FunctionSelectionAssigns a function to the multi-function digital inputs.Refer to pages 205 to 208 for descriptions of setting values.Note: Set unused terminals to F.Default: 14Min.: 0Max.: 9F 104H1-05(402)Multi-Function Digital InputTerminal S5 FunctionSelectionAssigns a function to the multi-function digital inputs.Refer to pages 205 to 208 for descriptions of setting values.Note: Set unused terminals to F.Default: 3 (0) <1>Min.: 0Max.: 9F104H1-06(403)Multi-Function Digital InputTerminal S6 FunctionSelectionAssigns a function to the multi-function digital inputs.Refer to pages 205 to 208 for descriptions of setting values.Note: Set unused terminals to F.Default: 4 (3) <1>Min.: 0Max.: 9F104H1-07(404)Multi-Function Digital InputTerminal S7 FunctionSelectionAssigns a function to the multi-function digital inputs.Refer to pages 205 to 208 for descriptions of setting values.Note: Set unused terminals to F.Default: 6 (4) <1>Min.: 0Max.: 9F104H1-08(405)Multi-Function Digital InputTerminal S8 FunctionSelectionAssigns a function to the multi-function digital inputs.Refer to pages 205 to 208 for descriptions of setting values.Note: Set unused terminals to F.Default: 8Min.: 0Max.: 9F 104<1> Value in parenthesis is the default setting when a 3-Wire initialization is performed (A1-03 = 3330).H1 Multi-Function Digital Input SelectionsH1-ooSetting Function Description Page0 3-Wire sequence Closed: Reverse rotation (only if the drive is set up for 3-Wire sequence)Terminals S1 and S2 are automatically set up for the Run command and Stop command. 1051 LOCAL/REMOTE selection Open: REMOTE (parameter settings determine the source of the frequency Reference 1 or 2(b1-01, b1-02 or b1-15, b1-16)Closed: LOCAL, digital operator is run and reference source –2 External reference 1/2 selection Open: Run command and frequency reference source 1 (determined by b1-01 and b1-02)Closed: Run command and frequency reference source 2 (determined by b1-15 and b1-16) –3 Multi-Step Speed Reference 1 When input terminals are set to Multi-Step Speed References 1 through 3, switchingcombinations of those terminals will create a multi-step speed sequence using the frequencyreferences set in d1-01 through d1-08. –4 Multi-Step Speed Reference 2 When input terminals are set to Multi-Step Speed References 1 through 3, switchingcombinations of those terminals will create a multi-step speed sequence using the frequencyreferences set in d1-01 through d1-08. –5 Multi-Step Speed Reference 3 When input terminals are set to Multi-Step Speed References 1 through 3, switchingcombinations of those terminals will create a multi-step speed sequence using the frequencyreferences set in d1-01 through d1-08. –6 Jog reference selection Closed: Jog frequency reference (d1-17) selected. Jog has priority over all other referencesources. –7 Accel/decel time selection 1 Used to switch between accel/decel time 1 (set in C1-01, C1-02) and accel/decel time 2 (setin C1-03, C1-04). –8 Baseblock command (N.O.) Closed: No drive output –B.7 H Parameters: Multi-Function TerminalsYASKAWA ELECTRIC TOEP C710616 41B YASKAWA AC Drive - A1000 Quick Start Guide 205B Parameter List