Sigma II User’s Manual Chapter 7: Using the Digital Operator7 - 87.1.6 Operation in Parameter Setting ModeFunctions can be selected or adjusted by setting parameters. There are two types ofparameters that can be set. One type requires value setting and the other requiresfunction selection. These two types use different setting methods.• With value setting, a parameter is set to a value within the specified range of theparameter.• With function selection, the functions allocated to each digit of theseven-segment LED panel indicator (five digits) can be selected.See Appendix B List of Parameters. Changing Parameter SettingsThe parameter settings can be used to change parameter data. Check the permittedrange of the parameters in Appendix B List of Parameters, before changing the data.The example below shows how to change parameter Pn507 from 100 to 85.Using the Hand-held Digital Operator1. Press the DSPL/SET key to select the parameter setting mode.2. Select the parameter number to set. (Pn507 is selected in this example.)Press the Left Arrow or Right Arrow key to select the digit. Theselected digit will flash.Press tthe Up Arrow or Down Arrow key to change the value.3. Press the DATA/ENTER key to display the current data for the parameterselected at step 2.4. Change the data as needed (to 85, in this example).Press the Left Arrow or Right Arrow key to select the digit. The selecteddigit will flash.Press the Up Arrow or Down Arrow key to change the value.Continue pressing the key until “00085” is displayed.