Sigma II User’s Manual Chapter 3: Wiring3 - 53.1.2 Three-Phase (200V) Main Circuit SpecificationsHostControllerConnect the SGDH servo amplifierto a Yaskawa host controller or toone made by another company.MEMOCON GL120, GL130with a motion module.Molded-Case CircuitBreaker (MCCB)Noise FilterMagnetic ContactorBrake Power SupplyRegenerative ResistorDigital OperatorPersonal ComputerEncoderCableEncoderConnectorJUSP-OPO2A-1Allows the user toset parameters oroperation referencesand to display opera-tion or alarm status.Communicationand control is alsopossible with apersonal computer.Cable model: YS-12Used to eliminate externalProtects the powerUsed for a servomotorConnect an external regenerativeline by shuttingOFF the circuitwhen overcurrentis detected.HI Seriesnoise from the power line.Turns the servoON and OFF.Install a surgesuppressor onthe magneticcontactor.with a brake.resistor to terminals B1 and B2 ifthe regenerative capacity isinsufficient.and JZSP-CMS00-1(cable)BrakepowersupplyMagneticMagneticcontactorcontactorPowersupplygroundlineNoise filterPower supplyThree-phase 200VACR S TMCCBRegenerativeresistor(optional)For 6kW or higher, an externalresistor is required.