Sigma II User’s Manual Chapter 7: Using the Digital Operator7 - 427.2.9 Initializing Parameter SettingsThis function is used to restore all the parameters to the default settings (standardfactory settings).Follow the procedure below to initialize parameter settings.Using the Hand-held Digital Operator1. Press the DSPL/SET key to select the auxiliary function mode.2. Select the parameter Fn005.Press the Left Arrow or Right Arrow key to select the digit.Press the Up Arrow or Down Arrow key to change the value.3. Press the DATA/ENTER key, and the display will be as shown below.4. Press the DSPL/SET key, and the display will be as shown below. Theparameters will be initialized.5. Press the DATA/ENTER key to return to the auxiliary function mode display.This completes the initialization of parameter settings.• Initialize the parameter settings with the servo OFF.• After performing the procedure, cycle the power to restore all the parameters to the default settings.IMPORTANTFlashing forone secondFlashing duringinitializationEnd