Trial Operation6.4.9 Motor Code Selection (MTR: C1-25)6 -12Precautions when Changing the Motor CodeAfter changing the Motor code, be sure to turn OFF the control power supply. Next, check that the DigitalOperator display is no longer lit, and then turn ON the power supply again. This operation will enable the newMotor code.Table 6.4 Motor Codes for Standard Spindle MotorsVoltageClassMotor InverterCapacityInverterCapacitySelection(C1-56)Motor Model MotorCode(C1-25)Motor Max.Speed(min−1)30 min./ContinuousRated Out-put (kW)Load Fac-tor MeterMax. Value(%)200 V Standard 23P7 04 UAASKA-04FZj 001 8,000 3.7/2.2 20225P5 05 UAASKA-06FZj 002 8,000 5.5/3.7 17827P5 06 UAASKA-08FZj 003 8,000 7.5/5.5 1642011 07 UAASKA-11FZj 004 6,000 11/7.5 1762015 08 UAASKA-15FZj 005 6,000 15/11 1642018 09 UAASKA-19FZj 006 6,000 18.5/15 1482022 0A UAASKA-22FZj 007 6,000 22/18.5 1432030 0B UAASKJ-30FZj 008 4,500 30/22 1642037 0C UAASKJ-37FZj 009 4,500 37/30 148Windingselection25P5 05 UAASKB-06FZj 062 6,000 (1,500) 5.5/3.7 178selection 27P5 06 UAASKB-08FZj 063 6,000 (1,500) 7.5/5.5 1642011 07 UAASKB-11FZj 064 6,000 (1,500) 11/7.5 1762015 08 UAASKB-15FZj 065 4,800 (1,000) 15/11 1642018 09 UAASKB-19FZj 066 4,800 (1,000) 18.5/15 1482022 0A UAASKB-22FZj 067 4,800 (1,000) 22/18.5 1432030 0B UAASKB-30FZj 068 4,800 (1,000) 30/20 180400 V Standard 45P5 25 UAASKA-06FZjOOE 102 8,000 5.5/3.7 17847P5 26 UAASKA-08FZjOOE 103 8,000 7.5/5.5 1644011 27 UAASKA-11FZjOOE 104 6,000 11/7.5 1764015 28 UAASKA-15FZjOOE 105 6,000 15/11 1644018 29 UAASKA-19FZjOOE 106 6,000 18.5/15 1484022 2A UAASKA-22FZjOOE 107 6,000 22/18.5 1434030 2B UAASKJ-30FZjOOE 108 4,500 30/22 1644037 2C UAASKJ-37FZjOOE 109 4,500 37/30 1484045 2D UAASKJ-45FZjOOE 10A 4,500 45/37 146Windingselection45P5 25 UAASKB-06FZjOOE 162 6,000 (1,500) 5.5/3.7 178selection 47P5 26 UAASKB-08FZjOOE 163 6,000 (1,500) 7.5/5.5 1644011 27 UAASKB-11FZjOOE 164 6,000 (1,500) 11/7.5 1764015 28 UAASKB-15FZjOOE 165 4,800 (1,000) 15/11 1644018 29 UAASKB-19FZjOOE 166 4,800 (1,000) 18.5/15 1484022 2A UAASKB-22FZjOOE 167 4,800 (1,000) 22/18.5 1434030 2B UAASKB-30FZjOOE 168 4,800 (1,000) 30/20 180Note: Values in parentheses are the maximum speed (min−1) of the low-speed windings.The maximum value of the load factor meter = (30-min rated output x 120%)/(continuous rated output) (%)6IMPORTANT