Dell IDRAC6 manuals
IDRAC6
Table of contents
- user guide
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- iDRAC6 Overview
- iDRAC6 Enterprise and vFlash Media
- Supported Platforms
- Supported Remote Access Connections
- Other Documents You May Need
- Getting Started With the iDRAC6
- Basic Installation of the iDRAC6
- Configuring Your System to Use an iDRAC6
- Software Installation and Configuration Overview
- Installing the Software on the Managed System
- Installing RACADM
- Updating the iDRAC6 Firmware
- Updating the iDRAC6 Firmware Using the Web-Based Interface
- Configuring a Supported Web Browser
- Viewing Localized Versions of the Web-Based Interface
- the Web Interface
- Accessing the Web Interface
- Logging In
- Logging Out
- Configuring the iDRAC6 NIC
- Configuring IP Filtering and IP Blocking
- Configuring Platform Events
- Configuring Platform Event Filters (PEF)
- Configuring E-Mail Alerts
- Configuring IPMI Using Web Interface
- Configuring iDRAC6 Users
- Securing iDRAC6 Communications Using SSL and Digital Certificates
- Certificate Signing Request (CSR)
- Generating a Certificate Signing Request
- Uploading a Server Certificate
- viewing a server certificate
- Configuring and Managing Active Directory
- Configuring and Managing Generic LDAP
- Updating the iDRAC6 Firmware/System Services Recovery Image
- iDRAC6 Firmware Rollback
- First Boot Device
- Remote File Share
- Internal Dual SD Module
- Viewing Internal Dual SD Module Status Using GUI
- Advanced iDRAC6 Configuration
- Configuring the iDRAC6 Settings to Enable SSH/Telnet
- Using a Telnet Console
- Using the Secure Shell (SSH)
- Configuring Linux for Serial Console During Boot
- Configuring iDRAC6 for Serial Connection
- Basic Mode and Direct Connect Terminal Mode
- Interface Communication Mode and Serial Console
- Connecting the DB-9 or Null Modem Cable for the Serial Console
- Configuring the Management Station Terminal Emulation Software
- Configuring HyperTerminal for Serial Console
- Configuring Serial and Terminal Modes
- Configuring Terminal Mode
- Configuring the iDRAC6 Network Settings
- Using RACADM Remotely
- RACADM Synopsis
- Enabling and Disabling the RACADM Remote Capability
- Frequently Asked Questions About RACADM Error Messages
- Configuring Multiple iDRAC6 Controllers
- Creating an iDRAC6 Configuration File
- Parsing Rules
- Modifying the iDRAC6 IP Address
- Configuring iDRAC6 Network Properties
- Frequently Asked Questions about Network Security
- iDRAC6 Users
- Public Key Authentication over SSH
- Web-Based Interface
- Uploading, Viewing, and Deleting SSH Keys Using RACADM
- Using the RACADM Utility to Configure iDRAC6 Users
- Adding an iDRAC6 User
- Removing an iDRAC6 User
- Service
- Prerequisites for Enabling Microsoft Active Directory Authentication for iDRAC6
- Exporting the Domain Controller Root CA Certificate to the iDRAC6
- Importing the iDRAC6 Firmware SSL Certificate
- Supported Active Directory Authentication Mechanisms
- Overview of the iDRAC Schema Extensions
- Accumulating Privileges Using Extended Schema
- Directory to Access Your iDRAC6
- Extending the Active Directory Schema
- Active Directory Users and Computers Snap-In
- Adding iDRAC Users and Privileges to Microsoft Active Directory
- Directory With Extended Schema Using the iDRAC6 Web-Based Interface
- Configuring Microsoft Active Directory With Extended Schema Using RACADM
- Standard Schema Active Directory Overview
- Single Domain Versus Multiple Domain Scenarios
- Configuring Standard Schema Microsoft Active Directory to Access iDRAC6
- Configuring Microsoft Active Directory With Standard Schema Using RACADM
- Testing Your Configurations
- Generic LDAP Directory Service
- Configuring Generic LDAP Directory Service Using RACADM
- Frequently Asked Questions about Active Directory
- Sign-On or Smart Card Login
- Prerequisites for Active Directory SSO and Smart Card Authentication
- Using Microsoft Active Directory SSO
- Logging Into iDRAC6 Using SSO
- Configuring Smart Card Authentication
- Configuring Active Directory Users for Smart Card Logon
- Logging Into the iDRAC6 Using the Smart Card
- Active Directory Smart Card Authentication
- Troubleshooting the Smart Card Logon in iDRAC6
- Frequently Asked Questions About SSO
- Using GUI Virtual Console
- Configuring Your Management Station
- Clear Your Browser's Cache
- Virtual Media Applications
- Supported Screen Resolutions and Refresh Rates
- Opening a Virtual Console Session
- Virtual Console Preview
- Using iDRAC6 Virtual Console (Video Viewer)
- Disabling or Enabling Local Server Video
- Launching Virtual Console and Virtual Media Remotely
- General Error Scenarios
- Frequently Asked Questions on Virtual Console
- Using the WS-MAN Interface
- Command Line Interface
- SM-CLP Features
- System Using VMCLI
- Creating a Bootable Image File
- Deploying the Operating System
- Using the VMCLI Utility
- Installing the VMCLI Utility
- VMCLI Parameters
- VMCLI Operating System Shell Options
- Configuring IPMI Using Web-Based Interface
- Serial Interface
- Virtual Media
- Windows-Based Management Station
- Linux-Based Management Station
- Running Virtual Media
- Booting From Virtual Media
- Installing Operating Systems Using Virtual Media
- Using Virtual Media When the Server's Operating System Is Running
- Frequently Asked Questions about Virtual Media
- Managing vFlash Partitions
- Configuring vFlash or Standard SD Card Using iDRAC6 Web Interface
- Configuring vFlash or Standard SD Card Using RACADM
- Enabling or Disabling the vFlash or Standard SD Card
- iDRAC6 Web Interface
- Creating a Partition Using an Image File
- Formatting a Partition
- Viewing Available Partitions
- Modifying a Partition
- Deleting Existing Partitions
- Downloading Partition Contents
- Booting to a Partition
- Creating a Partition
- Attaching or Detaching a Partition
- Frequently Asked Questions
- Management
- Power Inventory, Power Budgeting and Capping
- Viewing the Health Status of the Power Supply Units
- Using RACADM
- Viewing Power Budget
- Power Budget Threshold
- Viewing Power Monitoring
- Executing Power Control Operations on the Server
- Utility
- Starting the iDRAC6 Configuration Utility
- iDRAC6 LAN
- LAN Parameters
- Virtual Media Configuration
- Smart Card Logon
- LCD Configuration
- LAN User Configuration
- System Event Log Menu
- Monitoring and Alert Management
- Disabling the Windows Automatic Reboot Option
- Configuring PET
- Testing E-mail Alerting
- Testing the RAC SNMP Trap Alert Feature
- the Managed System
- Managing Power on a Remote System
- Main System Chassis
- Remote Access Controller
- Using the System Event Log (SEL)
- Using the Command Line to View System Log
- Using the POST Boot Logs
- Viewing the Last System Crash Screen
- the iDRAC6
- Using the Command Line
- Diagnostic commands
- Using the Trace Log
- Using the coredump
- Sensors
- Power Supplies Probes
- Voltage Probes
- Configuring Security Features
- Security Options for the iDRAC6 Administrator
- Disabling iDRAC6 Virtual Console
- Secure Sockets Layer (SSL)
- Accessing the SSL Main Menu
- Viewing a Server Certificate
- Configuring Services
- Enabling Additional iDRAC6 Security Options
- Configuring the Network Security Settings Using the iDRAC6 GUI
- Index
IDRAC6
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- iDRAC6 Enterprise Overview
- IPv6 Ready Logo Certification
- iDRAC6 Enterprise and vFlash Media
- Supported Platforms
- Supported Operating Systems
- Other Documents You May Need
- Configuring iDRAC6 Enterprise
- Configuration Tasks
- Configure iDRAC6 Users
- Configure Platform Events
- Configure Secure Sockets Layer (SSL)
- Configuring Networking Using the CMC Web Interface
- Configuring Networking for iDRAC6
- Viewing FlexAddress Mezzanine Card Fabric Connections
- FlexAddress MAC for iDRAC6
- Remote Syslog
- Remote File Share
- Updating iDRAC6 Firmware
- Executing the Firmware Update
- Verifying the Digital Signature for Linux DUPs
- Using iDRAC6 Web Interface
- Updating iDRAC6 Firmware Using RACADM
- Using the DOS Update Utility
- Clear Your Browser's Cache
- Using iDRAC6 Web Interface to Enable Discovery and Monitoring
- Using IT Assistant to View iDRAC6 Status and Events
- Station
- Configuring a Supported Web Browser
- Adding iDRAC6 to the List of Trusted Domains
- Setting the Locale in Linux
- Disabling the Whitelist Feature in Firefox
- Installing iDRAC6 Software on the Management Station
- Uninstalling RACADM
- Installing Telnet or SSH Clients
- Configuring the Backspace Key For Telnet Sessions
- Installing a TFTP Server
- Installing Dell Management Console
- Server
- Configuring the Managed Server to Capture the Last Crash Screen
- Disabling the Windows Automatic Reboot Option
- Using the Web Interface
- Accessing the Web Interface
- Logging Out
- Configuring iDRAC6 NIC
- Configuring IP Filtering and IP Blocking
- Configuring Platform Events
- Configuring Platform Event Filters (PEF)
- Configuring E-Mail Alerts
- Configuring IPMI Over LAN
- Adding and Configuring iDRAC6 Users
- Securing iDRAC6 Communications Using SSL and Digital Certificates
- Secure Sockets Layer (SSL)
- Accessing the SSL Main Menu
- Generating a New Certificate Signing Request
- Uploading a Server Certificate
- Viewing a Server Certificate
- Configuring and Managing Active Directory Certificates
- Configuring Active Directory (Standard Schema and Extended Schema)
- Viewing an Active Directory CA Certificate
- Configuring iDRAC6 Services
- Updating iDRAC6 Firmware Using the CMC
- Active Directory
- Prerequisites for Enabling Active Directory Authentication for iDRAC6
- Extended Schema Active Directory Overview
- Overview of iDRAC6 Schema Extensions
- Accumulating Privileges Using Extended Schema
- Configuring Extended Schema Active Directory to Access iDRAC6
- Active Directory Users and Computers Snap-In
- Adding iDRAC6 Users and Privileges to Active Directory
- Extended Schema Using iDRAC6 Web Interface
- Configuring Active Directory With Extended Schema Using RACADM
- Overview
- Single Domain Versus Multiple Domain Scenarios
- Configuring Standard Schema Active Directory to Access iDRAC6
- Configuring Active Directory With Standard Schema Using RACADM
- Testing Your Configurations
- Enabling SSL on a Domain Controller
- Certificate
- Using Active Directory to Log In to iDRAC6
- Using Active Directory Single Sign-On
- Logging Into iDRAC6 Using Single Sign-On
- Active Directory Certificate Validation
- Miscellaneous
- Authentication
- Logging Into iDRAC6 Using Active Directory Smart Card Authentication
- Enabling Kerberos Authentication
- Prerequisites for single sign-on and Active Directory Authentication Using Smart Card
- Using Smart Card
- Configuring Active Directory Users for Smart Card Logon
- iDRAC6 Login Scenarios with TFA and SSO
- Health of the Managed Server
- Integrated Dell Remote Access Controller 6 - Enterprise
- WWN/MAC
- Batteries
- POST
- Power Monitoring and Power Management
- Power Monitoring
- Power Budgeting
- Viewing Power Budget
- Power Control
- Serial Over LAN
- Configuring Serial Over LAN in iDRAC6 Web GUI
- Using Serial Over LAN (SOL)
- Model for the SOL Proxy
- Using SOL over PuTTY
- Using SOL over OpenSSH with Linux
- Opening SOL with SOL proxy
- Operating System Configuration
- Windows 2003 Enterprise
- Using GUI Console Redirection
- Supported Screen Resolutions and Refresh Rates
- Configuring Console Redirection and Virtual Media in iDRAC6 Web Interface
- Opening a Console Redirection Session
- Using the Video Viewer
- Synchronizing the Mouse Pointers
- Frequently Asked Questions
- Card for Use With iDRAC6
- Removing a vFlash Media Card
- Formatting the vFlash Media Card
- Viewing the vFlash Key Size
- Resetting the vFlash Media Card
- Configuring and Using Virtual Media
- Windows-Based Management Station
- Linux-Based Management Station
- Configuring Virtual Media
- Running Virtual Media
- Disconnecting Virtual Media
- Installing Operating Systems Using Virtual Media
- Using the RACADM Command Line Interface
- RACADM Subcommands
- Supported RACADM Interfaces
- Using local RACADM Commands
- Using the RACADM Utility to Configure iDRAC6
- Managing iDRAC6 Users with RACADM
- Adding an iDRAC6 User
- Removing an iDRAC6 User
- Testing iDRAC6 SNMP Trap Alert Feature
- Configuring PEF
- Configuring PET
- Configuring IP Filtering (IP Range)
- Configuring IP Filtering
- Configuring IP Blocking
- Configuring iDRAC6 Telnet and SSH Services Using Local RACADM
- Remote and SSH/Telnet RACADM
- Remote RACADM Usage
- Using an iDRAC6 Configuration File
- Configuration File Syntax
- Modifying iDRAC6 IP Address in a Configuration File
- Loading the Configuration File Into iDRAC6
- SM-CLP Command Line Interface
- System Management With SM-CLP
- SM-CLP Features
- Navigating the MAP Address Space
- Using the -level Option
- Server Power Management
- Updating iDRAC6 Firmware Using SM-CLP
- Using the WS-MAN Interface
- Supported CIM Profiles
- Deploying Your Operating System Using iVMCLI
- Creating a Bootable Image File
- Deploying the Operating System
- Line Interface Utility
- Installing the iVMCLI Utility
- Command Line Options
- iVMCLI Operating System Shell Options
- Using iDRAC6 Configuration Utility
- Starting iDRAC6 Configuration Utility
- iDRAC6 LAN
- LAN Parameters
- Virtual Media Configuration
- System Services
- Reset to Default
- System Event Log Menu
- Recovering and Troubleshooting the Managed System
- Trouble Indicators
- Hardware Trouble Indicators
- Problem Solving Tools
- Checking the System Event Log (SEL)
- Checking the Post Codes
- Viewing the Most Recent Boot Sequences
- Checking the Server Status Screen for Error Messages
- Viewing iDRAC6 Log
- Viewing System Information
- Identifying the Managed Server in the Chassis
- Managing Power on a Remote System
- Troubleshooting and Frequently Asked Questions
- help
- config
- getconfig
- getssninfo
- getsysinfo
- getractime
- setniccfg
- getniccfg
- getsvctag
- racreset
- racresetcfg
- getraclog
- clrraclog
- clrsel
- sslcsrgen
- sslcertupload
- sslcertdownload
- sslcertview
- testemail
- testtrap
- vmdisconnect
- clearasrscreen
- fwupdate
- krbkeytabupload
- vmkey
- coredump
- coredumpdelete
- ifconfig
- netstat
- ping6
- traceroute
- traceroute6
- remoteimage
- Database Group and Object Definitions
- idRacInfo
- idRacBuildInfo (Read Only)
- cfgOobSnmp
- cfgLanNetworking
- cfgDNSDomainName (Read/Write)
- cfgDNSRegisterRac (Read/Write)
- cfgDNSServer2 (Read/Write)
- cfgNicIpAddress (Read/Write)
- cfgNicUseDhcp (Read/Write)
- cfgNicVLanEnable (Read Only)
- cfgIPv6URL
- cfgIPv6Address1 (Read/Write)
- cfgIPv6AutoConfig (Read/Write)
- cfgIPv6DNSServer1 (Read/Write)
- cfgIPv6DNSServer2 (Read/Write)
- cfgIPv6Addr3PrefixLength (Read Only)
- cfgIPv6Addr4Length (Read Only)
- cfgIPv6Addr6PrefixLength (Read Only)
- cfgIPv6Addr7Length (Read Only)
- cfgIPv6Addr9PrefixLength (Read Only)
- cfgIPv6Addr10Length (Read Only)
- cfgIPv6Addr12PrefixLength (Read Only)
- cfgIPv6Addr13Length (Read Only)
- cfgIPv6Addr15PrefixLength (Read Only)
- cfgUserAdminIndex (Read Only)
- cfgUserAdminUserName (Read/Write)
- cfgUserAdminEnable (Read/Write)
- cfgEmailAlertEnable (Read/Write)
- cfgSessionManagement
- cfgSsnMgtSshIdleTimeout (Read/Write)
- cfgSerial
- cfgSerialTelnetEnable (Read/Write)
- cfgRhostsFwUpdateIpAddr (Read/Write)
- cfgRhostsSyslogEnable (Read/Write)
- cfgRhostsSyslogServer2 (Read/Write)
- cfgUserDomainName (Read/Write)
- cfgServerPowerCapWatts (Read Only)
- cfgServerPowerCapPercent (Read Only)
- cfgRacTuneHttpsPort (Read/Write)
- cfgRacTuneIpRangeMask
- cfgRacTuneIpBlkFailWindow
- cfgRacTuneConRedirEnable (Read/Write)
- cfgRacTuneConRedirPort (Read/Write)
- cfgRacTuneWebserverEnable (Read/Write)
- cfgRacTuneTimezoneOffset (Read/Write)
- ifcRacManagedNodeOs
- cfgRacSecurity
- cfgSecCsrLocalityName (Read/Write)
- cfgSecCsrEmailAddr (Read/Write)
- cfgVirMediaBootOnce (Read/Write)
- cfgVirtualFloppyEmulation (Read/Write)
- cfgIpmiLanPrivLimit (Read/Write)
- cfgIpmiPetCommunityName (Read/Write)
- cfgIpmiPetIPv6AlertDestIpAddr
- cfgIpmiPefIndex (Read/Write)
- cfgIpmiPefEnable (Read/Write)
- cfgIpmiPetAlertEnable (Read/Write)
- cfgSmartCardCRLEnable (Read/Write)
- cfgADRacName (Read/Write)
- cfgADDomainController1 (Read/Write)
- cfgADDomainController3 (Read/Write)
- cfgADGlobalCatalog3 (Read/Write)
- cfgStandardSchema
- cfgSSADRoleGroupPrivilege (Read/Write)
- cfgIpmiSol
- cfgIpmiSolSendThreshold (Read/Write)
- Glossary
- Index
manualsdatabase