Appendix CVoice Configuration Reference InformationVoice Port OperationUsers of equipment attached to a SmartSwitch 1800 Voice port can dial a long formnumber, or use any of the numbers defined in the SmartSwitch’s speed dial map table.Once the speed dial table has been configured, you should make the table available tothe voice and fax users. You can also configure the SmartSwitch to automatically diala speed dial number.Both the long and short numbers access a configured specific destination. When auser-entered speed dial or long-form number is used, the call can access any desti-nation (regardless of compatibility).Also see the Store and Forward Dialing, Variable Length Dialing, and Wild CardCharacter examples below for more information about how users of voice and faxequipment can initiate calls.Store and Forward DialingThe SmartSwitch 1800 supports store and forward dialing of speed dial numbers andextended dial digits. The extended dial digits can be defined in the map table and asso-ciated with a speed dial number, or entered by the user of attached equipment. Storeand forward dialing is enabled by setting the Extended Dial Digits parameter in VoiceSystem-Level Configuration (page 13-3) to a non-zero value. Individual voice/faxports (page 13-8) must be configured to identify how and what dial digits are for-warded. The following examples show system, port, and map table configurationentries that store and forward extended digits from user input and from map tableentries.