COPIER>IO>R-CONAd-dressBIT Description RemarksP001 2 While the screen is open, the values are updated periodically (with aninterval of 1 second).Display sensor status (HPS)P002 - No sensor allocated; 0 is always shown While the screen is open, the values are updated periodically (with aninterval of 1 second).ADJUST■ ADJ-XYCOPIER > ADJUST > ADJ-XYItem DescriptionADJ-XTitle Adj of img pstn in book mode: vert scanDetails To adjust the image reading start position (image leading edge position) in the vertical scanning directionat copyboard reading.When replacing the Main Controller PCB, enter the value of service label.When the non-image width is larger than the standard value, set the smaller value.When out of original area is copied, set the larger value.As the value is incremented by 1, the image position moves to the trailing edge side by 0.1mm.Use case • When replacing the Reader Unit• When replacing the CIS Unit (Scanner Unit)• When replacing the Main Controller PCBAdj/set/operate method Enter the setting value (switch negative / positive by * key) and press Apply key.Caution After the setting value is changed, write the changed value in the service label.Display/adj/set range -30 to 30Unit 0.1 mmDefault value 0ADJ-YTitle Adjustment of image position at copyboard reading (horizontal scanning direction)Details To adjust the image reading start position in the horizontal scanning direction at copyboard reading.When replacing the Main Controller PCB, enter the value of service label.When the non-image width is larger than the standard value, set the smaller value.When out of original area is copied, set the larger value.As the value is incremented by 1, the image position moves to the front by 0.1mm.Use case • When replacing the Reader Unit• When replacing the CIS Unit (Scanner Unit)• When replacing the Main Controller PCBAdj/set/operate method Enter the setting value (switch negative / positive by * key) and press Apply key.Caution After the setting value is changed, write the changed value in the service label.Display/adj/set range -10 to 10Unit 0.1 mmDefault value 0ADJ-Y-DFTitle Adj img pstn in ADF mode:horz scanDetails To adjust the image reading start position in the horizontal scanning direction at ADF reading.When replacing the Main Controller PCB, enter the value of service label.As the value is incremented by 1, the image position moves to the front by 0.1mm.Use case • When replacing the ADF• When replacing the CIS Unit (Scanner Unit)• When replacing the Main Controller PCBAdj/set/operate method Enter the setting value (switch negative / positive by * key) and press Apply key.Caution After the setting value is changed, write the changed value in the service label.Display/adj/set range -10 to 10Unit 0.1 mmDefault value 08. Service Mode266