COPIER > ADJUST > VIFADJItem DescriptionDetails To adjust the setting value of C-color primary transfer bias.Use case When an image failure occursAdj/set/operate method Enter the setting value (switch negative / positive by * key) and press Apply key.Display/adj/set range -5 to 5Default value 0Related service mode COPIER > ADJUS T > VIFADJ > TR1-HV-YCOPIER > ADJUS T > VIFADJ > TR1-HV-MCOPIER > ADJUS T > VIFADJ > TR1-HV-KTR1-HV-KTitle Adjustment of primary transfer bias setting value (Bk)Details To adjust the setting value of Bk-color primary transfer bias.Use case When an image failure occursAdj/set/operate method Enter the setting value (switch negative / positive by * key) and press Apply key.Display/adj/set range -5 to 5Default value 0Related service mode COPIER > ADJUST > VIFADJ > TR1-HV-YCOPIER > ADJUST > VIFADJ > TR1-HV-MCOPIER > ADJUST > VIFADJ > TR1-HV-CTR2SF-HVTitle Adjustment of secondary transfer bias setting value (front side)Details To adjust the setting value of secondary transfer bias (front side).Use case When an image failure occursAdj/set/operate method Enter the setting value (switch negative / positive by * key) and press Apply key.Display/adj/set range -5 to 5Default value 0Related service mode COPIER > ADJUST > VIFADJ > TR2BK-HVTR2BK-HVTitle Adjustment of secondary transfer bias setting value (back side)Details To adjust the setting value of secondary transfer bias (back side).Use case When an image failure occursAdj/set/operate method Enter the setting value (switch negative / positive by * key) and press Apply key.Display/adj/set range -5 to 5Default value 0Related service mode COPIER > ADJUST > VIFADJ > TR2SF-HVICL-HVTitle Adjustment of bias setting value for ITB cleaningDetails To adjust the bias setting value to be used for ITB cleaning.Use case When an image failure occursAdj/set/operate method Enter the setting value (switch negative / positive by * key) and press Apply key.Display/adj/set range -5 to 5Default value 0FU-TMPTitle Adjustment of setting value of Fixing Roller surface temperatureDetails To adjust the setting value of the surface temperature of the Fixing Roller.Use case When an image failure occursAdj/set/operate method Enter the setting value (switch negative / positive by * key) and press Apply key.Display/adj/set range -2 to 2Default value 08. Service Mode272