Numeric parameter setting modeNo. Parameter Allowable setting range07 Spare08 STORED_DIAL_MODE wait timer 0 to 65 sec09 Not in use10 T.30 T0 timer 55 sec principally11 T.30 T1 timer (for incoming transmission) 0 to 9999 (France: 3500, Others: 3000)12 Maximum incoming lines 0 to 65535 (line)0: without limitation13 T.30 EOL timer 500 to 3000 (set to 55 sec by default)14 Not in use15 Threshold between hokking nad on-hook 0 to 99916 Lead time to the first response when switching between FAX and TEL 0 to 917 Duration to activate pseudo-RBT cadence 0 to 99918 Duration to deactivate pseudo-RBT cadence (short) 0 to 99919 Duration to deactivate pseudo-RBT cadence (long) 0 to 99920 Duration to activate pseudo-ring cadence 0 to 99921 Duration to deactivate OFF Hook cadence (short) 0 to 99922 Duration to deactivate OFF Hook cadence (long) 0 to 723 to 24 Not in use25 CNG monitor duration while the answering device is activated 0 to 99926 to 28 Not in use29 Off-hook PCB duty settings(For NAC, setting can be made with SPL71100in special management mode.)20 (*10ms)30 to 48 Not in use49 NSX MODEL ID 0 to 409550 Not in use51 Threshold to detect hook 10 to 999952 Not in use53 Set DTMF calling counts when receiving FAX remotely 10 to 9999 (default 25)54 Set Busy Tone outgoing duration when using handset55 to 80 Not in useSetting of NCU Parameters■ TONE/PULSEOperation Method1. Setting of Tone ParametersOperate as follows, and change to the parameter setting mode.1. While "#NCU" is displayed, press "OK" key2. Press "#TONE" key3. Press "OK" key2. Setting of Pulse ParametersOperate as follows, and change to the pulse setting mode.1. While "#NCU" is displayed, press "OK" key2. Press "#PULSE" key3. press "OK" keyItem Function Setting rangeTONE 01; Tone signal sending time (PSTN) 10 to 9999 (msec)02; Minimum pause time (PSTN) 10 to 9999 (msec)PULSE PULSE FORM Pulse digit format 0 to DP ( N )1 to DP ( N+1 )2 to DP ( 10-N )PULSE NUM 01; Not in use02; Not in use03; Pulse dial make ratio 10 to 90 (%)8. Service Mode304