● Encryption Password• It is necessary to set a password during the export process because data such as the password of the address book set bythe user are encrypted when the DCM file is exported/imported.• The password must consist of 32 or less ASCII characters. A password exceeding 32 characters cannot be entered.• If a wrong password is entered at import, the encrypted setting values cannot be decoded, and the import of the settingvalues end with an error.• It is necessary to specify a password even when the data to be exported does not contain any data to be encrypted. However,in the case of export from service mode, it is not necessary to enter the password, and the password (28282828) is enteredautomatically.■ Specifications Related to Department ID Management• Department ID information is exported only when the Department ID management setting is enabled.Regardless of the stateof the department ID management setting, the state of department ID management (enabled/disabled) and the systemadministrator information are exported. The department ID counter is not exported.• When importing department ID information, the import process differs depending on the combination of the department IDset in the host machine and the department ID set in the data to be imported."ID_1" has not been set in the hostmachine."ID_1" has been set in the host machine."ID_1" has been set in the data to be impor-ted.Information of "ID_1" is imported. The de-partment ID counter is "0".Information excluding the department IDcounter information of "ID_1" in the host ma-chine is imported."ID_1" has not been set in the data to be im-ported.Not overwritten Information of "ID_1" is deleted.Department ID information has not been setin the data to be imported.Not overwritten Not overwritten* ID_1 indicates a department ID.■ Specifications during Execution of a Process● Control Panel/Remote UI during a Process• During export or import, a screen is displayed to prohibit operation from the Control Panel and remote UI.• During export or import, the keys excluding the energy saver key are disabled.● Cancel during a ProcessDuring export or import, the process cannot be canceled by user operation.● Behavior when a Service Error OccursEven when a service error has occurred, export and import can be executed.However, this does not include errors which disable the DCM function.● Export/import process from service modeWhen performing export/import process from service mode, no error is displayed even when an error has occurred.● Process after ImportAfter the setting file is imported using the DCM function, the following process is performed.Import method ProcessOperation Panel When the import process is completed successfully, the device will be restarted in 25 seconds.Remote UI When the import process is completed successfully, the device will be restarted in 25 seconds.However, the device will not be restarted if only the address book is imported.iW EMC /MC DCM Plug-inWhen the import process is completed successfully, the device will be restarted in 90 seconds (time for DCMPlug-in to obtain the import result).However, the device will not be restarted if only the address book is imported.2. Technical Explanation61