In down sequence, 50 cpm or 40 cpm mode is initiated to suit the surfacetemperature of the upper fixing roller.Normal sequence will be initiated when the surface temperature of the upper fixingroller reaches a specific level (Table 6-104); however, once copying has beensuspended, WMUP sequence will be used until the surface temperature of the upperfixing roller reaches 200°C.If any of the foregoing levels of surface temperature is detected during copyingoperation, the machine starts WMUP sequence while indicating the remaining numberof copies on the control panel. When the Copy Start key is pressed as in during STBY,the remaining number of copies are made.Figure 6-103210°C205°C200°C195°C(205°C)(210°C) (212°C) (210°C)Power switchSWONWMUPMain heater (H1)Sub heater (H2)Main motor (M1)Wait indicationSTBY200°CAbout 20 sec afterend of CNTR2INTR CNTR1 CNTR2 LSTR STBY INTR CNTR1 CNTR2 AER SCFWSCRWSCRF SCRV LSTRCopy Start keyONON in green ON in orange